MERIDIAN, ID —
OSHA Inspection: RAMSEY CONSTRUCTION, LLC
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of RAMSEY CONSTRUCTION, LLC in 1495 SOUTH TECH LANE, MERIDIAN, ID 83642 (NAICS 236116). OSHA activity number 341088219.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RAMSEY CONSTRUCTION, LLC
- Site address
- 1495 SOUTH TECH LANE
- City
- MERIDIAN
- State
- ID
- ZIP
- 83642
- Mailing
- 7950 HORSESHOE BEND RD, SUITE 106, BOISE, ID 83714
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236116
- Employees
- 2
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.20 B01
- Issued
- Dec 3, 2015
- Abate by
- Dec 30, 2015
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.20(b)(1): The employer did not initiate and maintain such programs as may be necessary to comply with this part. a) Overland Park Apartments: On or about November 16, 2015, and at times prior thereto, the employer had not developed and/or implemented an accident prevention program to address hazards to which their employees and/or the employees of subcontractors are exposed. Hazards include but are not limited to falls from the lack of hand railing in stairwells, unguarded decks and/or framing activities at elevated heights without the use of fall protection, fire hazards while employees were observed smoking in the wood structures without fire suppression equipment in place, misuse of ladders and/or overhead hazards. Note: Abatement certification IS required for this item.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1926.20 B02
- Issued
- Dec 3, 2015
- Abate by
- Dec 30, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.20(b)(2): The employer did not initiate and maintain a safety program which provides for frequent and regular inspections of jobsites, materials, and equipment to be made by a competent person: a) Overland Park Apartments: On or about November 16, 2015, and at times prior thereto, the employer did not perform effective frequent and regular inspections of sites that they controlled to identify, correct and/or eliminate hazards to which their employees and/or the employees of subcontractors were exposed. Hazards include but are not limited to falls from the lack of hand railing in stairwells, unguarded decks and/or framing activities at elevated heights without the use of fall protection, fire hazards while employees were observed smoking in the wood structures without fire suppression equipment in place, misuse of ladders and/or overhead hazards. Note: Abatement certification IS required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B01
- Issued
- Dec 3, 2015
- Abate by
- Dec 30, 2015
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a) Overland Park Apartments: On or about November 16, 2015, the controlling employer, Ramsey Construction LLC did not ensure that its sub-contractors protected their employees while they accessed decks without a completed guardrail system was not in place. Employees were exposed to a 10 foot 6 inch fall hazard from the second floor balcony and/or an approximate 20 foot fall from the third level balcony to the ground level below. Note) Abatement certification IS required for this item.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1926.501 B13
- Issued
- Dec 3, 2015
- Abate by
- Dec 30, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.501(b)(13): Employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system or personal fall arrest systems: (a) Overland Park Apartments, Building J: On or about November 16, 2015 and at times prior thereto, the controlling contractor did not ensure that its sub-contractor protected its employees from a potential 30 foot fall hazards while involved in sheathing activities. Note: Abatement certification IS required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1052 C01
- Issued
- Dec 3, 2015
- Abate by
- Dec 30, 2015
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1926.1052(c)(1): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail and one stairrail system along each unprotected side or edge: (a) Overland Park Apartments, Building I: On or about November 16, 2015 and at times prior thereto, the stairwell consisting of 18 steps to 2nd level and an additional 18 steps to the third level of this multi-story residential structure. Note: Abatement certification IS required for this item.
Recent events (2)
- — I (S) $600
- — Z (S) $1200
1926.150 C01 I
- Issued
- Dec 3, 2015
- Abate by
- Dec 30, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.150(c)(1)(i): A fire extinguisher, rated not less than 2A, was not provided for each 3,000 square feet of the protected building area, or major fraction thereof: a) Overland Park Apartments: On or about November 16, 2015 and at times prior thereto, as the controlling employer, a fire extinguisher was not provided in buildings D, I and/or J. Note: Abatement certification IS required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Ramsey Construction, LLC
View Ramsey Construction, LLC's full OSHA safety record →
More inspections in this industry (NAICS 236116)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341088219.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.