Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: KELLEY BEAN CO.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of KELLEY BEAN CO. in 4498 440 RD., HAY SPRINGS, NE 69347 (NAICS 493130). OSHA activity number 341095206.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Kelley Bean CO. — free Get an email when a new federal OSHA severe-injury report for Kelley Bean CO. is published. One employer, no account, unsubscribe in one click.
Establishment
KELLEY BEAN CO.
Site address
4498 440 RD.
City
HAY SPRINGS
State
NE
ZIP
69347
Mailing
1520 AVE. B, SCOTTSBLUFF, NE 69361
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493130
Employees
1
Ownership type
A

3 citations on file for this inspection.

1910.215 A04

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 30, 2015
Penalty
Initial $3,825 · Current $2,678 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:   The employer is failing to protect employees from laceration hazards by not properly guarding equipment.  The work rest on the bench grinder in the maintenance shop was not adjusted adjacent to the wheel to the required 1/8" gap.  The gap measured at approximately 3/8".
Recent events (2)
  • — I (S) $2677.5
  • — Z (S) $3825

1910.215 B09

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 30, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:   The employer is failing to ensure that the tongue guard of the bench grinder is properly adjusted to protect employees from laceration hazards.  The tongue guard on the grinder in question was not correctly adjusted at the time of the inspection.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G01

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 30, 2015
Penalty
Initial $3,825 · Current $2,678 Reduced
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:   The employer is failing to ensure that the areas in front of circuit breaker panel boxes are free from obstruction and able to be readily accessed.  The panel box located in the Maintenance Building was blocked by numerous pieces of equipment and materials.  This impedes access to the box in an emergency situation in which the electricity would need to be turned off at the box.
Recent events (2)
  • — I (S) $2677.5
  • — Z (S) $3825

View Kelley Bean CO.'s full OSHA safety record →