OSHA Inspection: WORTHINGTON INDUSTRIES

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of WORTHINGTON INDUSTRIES in 300 E BREED STREET, CHILTON, WI 53014 (NAICS 332439). OSHA activity number 341101293.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Worthington Industries — free Get an email when a new federal OSHA severe-injury report for Worthington Industries is published. One employer, no account, unsubscribe in one click.
Site address
300 E BREED STREET
City
CHILTON
State
WI
ZIP
53014
Mailing
300 E BREED STREET, CHILTON, WI 53014
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332439
Employees
350
Ownership type
A

5 citations on file for this inspection.

1910.147 C04 II

Other-than-serious 1 instance 1 exposed
Issued
Apr 12, 2016
Abate by
Jun 10, 2016
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.147(c)(4)(ii): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following:      a. On or about November 29, 2015, the employer did not have an adequate written Lockout procedure for employees working on the #2 Atmospheric Generator.  The written procedure developed did not address the chemical hazard of Carbon Monoxide.    b. On or about November 29, 2015, the employer did not have an adequate written Lockout procedure for employees working on the #2 Furnace.  The written procedure developed did not address thermal hazards of the equipment.
Recent events (2)
  • — I (O) $7000
  • — Z (S) $7000

1910.147 C06 I

Other-than-serious 1 instance 1 exposed
Issued
Apr 12, 2016
Abate by
Jun 10, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed:      a. On or about November 29, 2015, the employer had not completed the required periodic inspections of the Lockout procedure for the #2 Furnace.    b. On or about November 29, 2015, the employer had not completed the required periodic inspections of the Lockout procedure for the #2 Atmospheric Generator.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.147 D

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Apr 12, 2016
Abate by
May 10, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):   a.  On or about November 29, 2015, employees were exposed to chemical hazards associated with exhaust gases when they engaged in repair activities on the #2 furnace. The atmosphere generator was not locked out and de-energized prior to the employee engaging in the servicing/maintenance activity.      As a result, the remaining applicable energy control elements, involving machine isolation [1910.147(d)(3)], lockout/tagout device application [1910.147(d)(4)], dissipation of residual energy [1910.147(d)(5)(i)], and verification of isolation [1910.147(d)(6)] were not implemented to protect employees from chemical hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1000 A02

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Apr 12, 2016
Abate by
May 10, 2016
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.1000(a)(2): Employee(s) were exposed to an airborne concentration of Carbon Monoxide listed in Table Z-1 in excess of the 8 hour Time Weighted Average concentration of 50 ppm:  a.  On or about November 29, 2015, an employee replacing a malfunctioning fan on furnace #2 was exposed to carbon monoxide (CO) at 3.79 times the OSHA PEL of 50 ppm.  3.79 times the OSHA PEL is equivalent to an 8 hour Time Weighted Average (TWA) concentration of 189.7 ppm CO.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7000

1910.1000 E

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Apr 12, 2016
Abate by
May 10, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1000(e): Feasible administrative or engineering controls were not determined and implemented to achieve compliance with the limits prescribed in 29 CFR 1910.1000(a) through (d).  On or about November 29, 2015, the employer located at 300 E. Breed Street Chilton, WI 53014 did not implement feasible administrative controls to achieve compliance with the limits prescribed in 29 CFR 1910.1000(a) through (d):  a.  Feasible administrative controls might include:         1.  An adequate Lock Out/Tag Out procedure.         2.  Assurance that employees understand and follow the Lock Out/Tag Out procedure.         3.  Personal Exposure Monitoring.  b.  Feasible engineering controls might include:         1.  Additional local ventilation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Worthington Industries's full OSHA safety record →