VANDALIA, IL —
OSHA Inspection: HARDWOODS, MATS, & BEAMS, INC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of HARDWOODS, MATS, & BEAMS, INC in 1517 N. 700TH ST., VANDALIA, IL 62471 (NAICS 321999). OSHA activity number 341147759.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HARDWOODS, MATS, & BEAMS, INC
- Site address
- 1517 N. 700TH ST.
- City
- VANDALIA
- State
- IL
- ZIP
- 62471
- Mailing
- 1517 N. 700TH ST., VANDALIA, IL 62471
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321999
- Employees
- 24
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.101 B
- Issued
- Jun 6, 2016
- Abate by
- Jun 16, 2016
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1910.101(b): Section 3.4.4, Compressed Gas Association Pamphlet P-1-1965, as incorporated by reference in Sec. 1910.6: Compressed gas cylinder(s) not in use were not properly supported to prevent them from being knocked over: A. The employer failed to ensure that one (1) K size (244CuFt) compressed gas cylinder, located in the Band Mill, containing oxygen was properly supported. B. The employer failed to ensure that one (1) K size (244CuFt) compressed gas cylinder, located in the Big Mill, containing argon was properly supported.
Recent events (3)
- — A (S) $1600
- — I (S) $1040
- — Z (S) $1600
1910.147 C01
- Issued
- Jun 6, 2016
- Abate by
- Aug 1, 2016
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: The employer did not establish an energy control program for employees who were performing serving operations on equipment such as, but not limited to, Wood-Mizer sawmill. Servicing operations included, but not limited to, blade changing.
Recent events (3)
- — A (S) $1600
- — I (S) $1040
- — Z (S) $1600
1910.147 D
- Issued
- Jun 6, 2016
- Abate by
- Aug 1, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): On or about 12/29/2015, employees were exposed to machine hazards associated with moving parts and in-going nip points during servicing and blade changing operations, of AWMV Wood-Mizer, located in the Band Mill area. The employer failed to implement energy control application steps as the machine was not shut down or turned off to perform servicing work [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(I)], and verification of isolation [(d)(6), were not implemented to protect employees from machine servicing hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 L01 I
- Issued
- Jun 6, 2016
- Abate by
- Aug 1, 2016
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): On or about 12/29/2015, the employer did not ensure that employees who were operating a Hyster Fork Truck had successfully completed a training program.
Recent events (3)
- — A (S) $2000
- — I (S) $1300
- — Z (S) $2000
1910.178 L06
- Issued
- Jun 6, 2016
- Abate by
- Aug 1, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l): On or about 12/29/2015, the employer did not ensure that each forklift operator had a written training and evaluation certification as required by the standard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 G01 VII B
- Issued
- Jun 6, 2016
- Abate by
- Jun 16, 2016
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1910.303(g)(1)(vii)(B): Outdoor electric equipment was not installed in suitable enclosures and was not protected from accidental contact by unauthorized personnel, or by vehicular traffic, or by accidental spillage or leakage from piping systems. No architectural appurtenance or other equipment may be located in the working space required by paragraph (g)(1)(i) of this section. The outdoor electrical feeder that is located on the back of the Big Mill building, was damaged and was not installed in a suitable enclosure or protected from accidental contact.
Recent events (3)
- — A (S) $2800
- — I (S) $1820
- — Z (S) $2800
1910.305 G01 IV A
- Issued
- Jun 6, 2016
- Abate by
- Jun 10, 2016
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: Flexible cords and cables were used as permanent wiring when: A. An orange flexible (extension) cord ran from an outlet located on a building next to the Band Mill to an area under the mill machines. B. A yellow flexible (extension) cord was ran from the orange extension cord to provide power to a multi tap outlet extension cord. C. A yellow multi-tap outlet extension cord was ran from the yellow extension cord to provide power to a circular saw and an orange extension cord. D. An orange extension cord was ran from a yellow multi-tap outlet extension cord and to the other side of the mill machine to provide power to a portable electrically powered hand tool.
Recent events (3)
- — A (S) $2800
- — I (S) $1820
- — Z (S) $2800
More inspections at Hardwoods, Mats, & Beams, INC
View Hardwoods, Mats, & Beams, INC's full OSHA safety record →
More inspections in this industry (NAICS 321999)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341147759.