Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CALIFORNIA ARMY NATIONAL GUARD - FMS #1

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CALIFORNIA ARMY NATIONAL GUARD - FMS #1 in 950 N. CUCAMUNGA AVE., ONTARIO, CA 91764 (NAICS 811111). OSHA activity number 341244218.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch California Army National Guard - FMS #1 — free Get an email when a new federal OSHA severe-injury report for California Army National Guard - FMS #1 is published. One employer, no account, unsubscribe in one click.
Site address
950 N. CUCAMUNGA AVE.
City
ONTARIO
State
CA
ZIP
91764
Mailing
950 N. CUCAMUNGA AVE., ONTARIO, CA 91764
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811111
Employees
12
Ownership type
D

7 citations on file for this inspection.

1910.36 D01

Serious Gravity 5 1 instance 12 exposed
Issued
Apr 20, 2016
Abate by
May 16, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge:  Bays 1-3: Employees were exposed to delayed access to the emergency exit where the exit access door could be locked from the other side.
Recent events (1)
  • — Z (S) $0

1910.178 L02 II

Serious Gravity 5 1 instance 12 exposed
Issued
Apr 20, 2016
Abate by
May 16, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(2)(ii): The employer did not ensure that each operator had successfully completed the training consisting of a combination of formal instruction (e.g., lecture, discussion, interactive computer learning, video tape, written material), practical training (demonstrations performed by the trainer and practical exercises performed by the trainee), and evaluation of the operator's performance in the workplace.  Motor Pool: The employer did not provide practical demonstration or evaluation of operator performance following an online powered industrial truck training program, exposing employees to struck by injuries.
Recent events (1)
  • — Z (S) $0

1910.334 A02 II

Serious Gravity 1 1 instance 12 exposed
Issued
Apr 20, 2016
Abate by
May 16, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service:  Break room: A power strip used to provide 120VAC service to a television had a melted and deformed case exposing employees to potential burns or electrical shock from the damaged equipment.
Recent events (1)
  • — Z (S) $0

1904.32 A02

Repeat 1 instance 12 exposed
Issued
Apr 20, 2016
Abate by
May 16, 2016
Penalty
Initial $0 · Current $0
29 CFR 1904.32(a)(2): The employer did not create an OSHA 300A Form or equivalent.  At the facility: On or about February 10, 2016, the employer failed to create the annual summary of work-related injuries and illnesses for 2015.  The California Army National Guard was previously cited for a violation of this occupational safety and health standard 29 CFR 1904.32(a)(2), which was contained in OSHA inspection number 107724, citation number 3, item number 1, and was affirmed as a final order on January 10, 2012, with respect to a workplace located at 2000 Stimson Road, Stockton, CA 95206.
Recent events (1)
  • — Z (R) $0

1904.40 A

Repeat 1 instance 12 exposed
Issued
Apr 20, 2016
Abate by
May 16, 2016
Penalty
Initial $0 · Current $0
29 CFR 1904.40(a): Copies of records kept under Part 1904 requested by an authorized government representative were not provided within four (4) business hours:  At the facility: On or about February 10, 2016, the employer did not provide copies of the 300A Form or equivalent for the years 2015, 2013, 2012, and 2011.  The California Army National Guard was previously cited for a violation of this occupational safety and health standard 29 CFR 1904.40(a), which was contained in OSHA inspection number 107724, citation number 4, item number 1, and was affirmed as a final order on January 10, 2012, with respect to a workplace located at 2000 Stimson Road, Stockton, CA 95206.
Recent events (1)
  • — Z (R) $0

1910.36 E01

Repeat Gravity 5 2 instances 12 exposed
Issued
Apr 20, 2016
Abate by
May 16, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.36(e)(1): A side-hinged door was not used to connect any room to an exit route.  (a) Changing room: A vertical rolling bay door was designated as an exit door exposing employees to fire or struck by hazards during an emergency.  (b) Bay 4: A vertical rolling bay door was designated as an exit door exposing employees to fire or struck by hazards during an emergency.  The California Army National Guard was previously cited for a violation of this occupational safety and health standard 29 CFR 1910.36(e), which was contained in OSHA inspection number 898787, citation number 1, item number 1, and was affirmed as a final order on May 9, 2013, with respect to a workplace located at Highway 101, Camp Roberts CIF Warehouse, San Miguel, CA 93451
Recent events (1)
  • — Z (R) $0

1910.303 B02

Repeat Gravity 1 2 instances 12 exposed
Issued
Apr 20, 2016
Abate by
May 16, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  (a) Break room: A power strip was used to provide 120VAC electrical service to a microwave, exposing employees to electrical shock.  (b) Break room: A power strip had an extension cord spliced into the case as a replacement for the original flexible cord, creating an electrical shock hazard for employees.    The California Army National Guard was previously cited for a violation of this occupational safety and health standard 29 CFR 1910.303(b)(2), which was contained in OSHA inspection number 898988, citation number 1, item number 4, and was affirmed as a final order on May 9, 2013, with respect to a workplace located at Highway 101, Camp Roberts Bldg. 14301 Range Control, San Miguel, CA 93451    The California Army National Guard was previously cited for a violation of this occupational safety and health standard 29 CFR 1910. 303(b)(2), which was contained in OSHA inspection number 898511, citation number 1, item number 4, and was affirmed as a final order on May 9, 2013, with respect to a workplace located at Highway 101, Camp Roberts Bldg. 101, San Miguel, CA 93451
Recent events (1)
  • — Z (R) $0

View California Army National Guard - FMS #1's full OSHA safety record →