Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: STROM ENGINEERING CORPORATION

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of STROM ENGINEERING CORPORATION in 1500 WEST MAIN ST., LOUISVILLE, OH 44641 (NAICS 332813). OSHA activity number 341271567.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Strom Engineering Corporation — free Get an email when a new federal OSHA severe-injury report for Strom Engineering Corporation is published. One employer, no account, unsubscribe in one click.
Site address
1500 WEST MAIN ST.
City
LOUISVILLE
State
OH
ZIP
44641
Mailing
10505 WAYZATA BOULEVARD, MINNETONKA, MN 55305
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332813
Employees
57
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 I

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Apr 8, 2016
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  On or about January 28, 2016, the employer failed to ensure employees performing cleaning the T2HI/4HI Reversing Temper Mill utilized lockout/tagout. An employee entered a maintenance door to clean the rollers while the machine was still operating.
Recent events (3)
  • — F (S) $0
  • — C (S) $7000
  • — Z (S) $7000

1910.147 D

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Apr 8, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):  On January 28, 2016 and prior, the employer failed to ensure employees cleaning the 2HI/$hi Reversing Temper Mill performed all steps of lockout/tagout. An employees hand was caught in the crimping assembly when the machine cycled while he was inside the machine cleaning the roller:   Employees were exposed to machine hazards associated with electrical and pressurized pneumatic energy. The employer failed to implement energy control application steps as the machine was not shut down or turned off to perform the servicing work. As a result, the remaining applicable energy control elements, involving preparation for shutdown [(d)(1)] , machine or equipment shutdown [(d)(2)], machine or equipment isolation [(d)(3)], lockout/tagout device application [(d)(4)], dissipation of residual energy [(d)(5)(I)], and verification of isolation [(d)(6)] were not implemented to protect employees from machine servicing hazards.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

View Strom Engineering Corporation's full OSHA safety record →