LOUISVILLE, OH —
OSHA Inspection: STROM ENGINEERING CORPORATION
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of STROM ENGINEERING CORPORATION in 1500 WEST MAIN ST., LOUISVILLE, OH 44641 (NAICS 332813). OSHA activity number 341271567.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STROM ENGINEERING CORPORATION
- Site address
- 1500 WEST MAIN ST.
- City
- LOUISVILLE
- State
- OH
- ZIP
- 44641
- Mailing
- 10505 WAYZATA BOULEVARD, MINNETONKA, MN 55305
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332813
- Employees
- 57
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C04 I
- Issued
- Apr 8, 2016
- Penalty
- Initial $7,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about January 28, 2016, the employer failed to ensure employees performing cleaning the T2HI/4HI Reversing Temper Mill utilized lockout/tagout. An employee entered a maintenance door to clean the rollers while the machine was still operating.
Recent events (3)
- — F (S) $0
- — C (S) $7000
- — Z (S) $7000
1910.147 D
- Issued
- Apr 8, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): On January 28, 2016 and prior, the employer failed to ensure employees cleaning the 2HI/$hi Reversing Temper Mill performed all steps of lockout/tagout. An employees hand was caught in the crimping assembly when the machine cycled while he was inside the machine cleaning the roller: Employees were exposed to machine hazards associated with electrical and pressurized pneumatic energy. The employer failed to implement energy control application steps as the machine was not shut down or turned off to perform the servicing work. As a result, the remaining applicable energy control elements, involving preparation for shutdown [(d)(1)] , machine or equipment shutdown [(d)(2)], machine or equipment isolation [(d)(3)], lockout/tagout device application [(d)(4)], dissipation of residual energy [(d)(5)(I)], and verification of isolation [(d)(6)] were not implemented to protect employees from machine servicing hazards.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
More inspections at Strom Engineering Corporation
View Strom Engineering Corporation's full OSHA safety record →
More inspections in this industry (NAICS 332813)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341271567.