Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BOWLMOR-AMF

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of BOWLMOR-AMF in 5155 W. TUSCARAWAS ST., CANTON, OH 44708 (NAICS 713950). OSHA activity number 341315042.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bowlmor-Amf — free Get an email when a new federal OSHA severe-injury report for Bowlmor-Amf is published. One employer, no account, unsubscribe in one click.
Establishment
BOWLMOR-AMF
Site address
5155 W. TUSCARAWAS ST.
City
CANTON
State
OH
ZIP
44708
Mailing
5155 W. TUSCARAWAS ST., CANTON, OH 44708
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
713950
Employees
17
Ownership type
A

5 citations on file for this inspection.

1910.23 E01

Other-than-serious 48 instances 5 exposed
Issued
Jul 15, 2016
Abate by
Aug 31, 2016
Penalty
Initial $4,000 · Current $500 Reduced
29 CFR 1910.23(e)(1): Standard railing(s) did not consist of top rail, intermediate rail and/or posts and/or did not have a vertical height of 42 inches (106.7 cm) nominal from upper surface of top rail to floor, platform runway, or ramp level:      On or about March 08, 2016, employees tasked with servicing/maintaining the forty-eight (48) pin setting machines, located in the machine area of the bowling center, were not protected from a fall hazard more than forty-eight (48) inches because the corresponding hand rails were missing mid-rails.
Recent events (3)
  • — F (O) $500
  • — C (S) $4000
  • — Z (S) $4000

1910.26 C01

Other-than-serious 1 instance 2 exposed
Issued
Jul 15, 2016
Abate by
Aug 10, 2016
Penalty
Initial $7,000 · Current $250 Reduced
29 CFR 1910.26(c)(1): Good safe practices in the use and care of ladder equipment were not employed by the users to get maximum serviceability, safety, and to eliminate unnecessary damage of equipment:          On or about March 08, 2016, while in the process of troubleshooting lane #37 an employee; who had been using a portable 3 ft. metal step ladders to ascend and descend the pin setting equipment, fell when the step ladder (which was not fully extended) kicked back/out and caused the ladder to tip over. The employer failed to ensure that safe work practices in the use of portable metal step ladders were established; implemented and their use enforced in that, the hardware connections for the ladders was not inspected prior to each use creating a fall hazard.
Recent events (3)
  • — F (O) $250
  • — C (S) $7000
  • — Z (S) $7000

1910.37 A03

Other-than-serious 1 instance 3 exposed
Issued
Jul 15, 2016
Abate by
Aug 10, 2016
Penalty
Initial $4,000 · Current $250 Reduced
29 CFR 1910.37(a)(3):  Exit routes must be free and unobstructed. No materials or equipment may be placed, either permanently or temporarily, within the exit route. The exit access must not go through a room that can be locked, such as a bathroom, to reach an exit or exit discharge, nor may it lead into a dead-end corridor. Stairs or a ramp must be provided where the exit route is not substantially level:      On or about March 08,2016, the doorway threshold of the exit discharge was not provided with stairs and/or a ramp. Employees who use the exit route when receiving deliveries and/or as an exit discharge in the event of an emergency are exposed to potential trip/fall hazards of approximately 15.5 - 16 inches.
Recent events (3)
  • — F (O) $250
  • — C (S) $4000
  • — Z (S) $4000

1910.219 I01

Serious Gravity 10 2 instances 4 exposed
Issued
Jul 15, 2016
Penalty
Initial $7,000 · Current $12,000
29 CFR 1910.219(i)(1): Screw(s) or bolt(s) used in revolving collar(s) projected beyond the largest periphery of the collar:       On or about March 08, 2016, the employer failed to ensure that the pin distributor on lanes including; but not limited to, lane #37 were equipped with a flush screw/bolt/pin in the revolving collar of the distributor clutch mechanism. An employee in the process of troubleshooting the machinery was injured when his finger inadvertently got caught by the head of an Allen head capped screw on the rotating/revolving collar.
Recent events (3)
  • — F (S) $12000
  • — C (S) $7000
  • — Z (S) $7000

1910.305 B01 II

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Jul 15, 2016
Penalty
Initial $4,000 · Current $0 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:    On or about March 08, 2016, the employer failed to ensure that the unused openings of the 220 volt electrical distribution panel box, located in the machine area behind lane 30 - 48, were effectively closed.  Employees tasked with completing servicing and/or maintenance activities are potentially exposed to electrical hazards if inadvertent contact with the internal wires were to occur.
Recent events (3)
  • — F (S) $0
  • — C (S) $4000
  • — Z (S) $4000

View Bowlmor-Amf's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341315042.