Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CPG INTERNATIONAL LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CPG INTERNATIONAL LLC in 894 PRAIRIE RD., WILMINGTON, OH 45177 (NAICS 326113). OSHA activity number 341323079.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch CPG International LLC — free Get an email when a new federal OSHA severe-injury report for CPG International LLC is published. One employer, no account, unsubscribe in one click.
Site address
894 PRAIRIE RD.
City
WILMINGTON
State
OH
ZIP
45177
Mailing
894 PRAIRIE RD., WILMINGTON, OH 45177
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326113
Employees
150
Ownership type
A

4 citations on file for this inspection.

1910.147 C04 I

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Apr 28, 2016
Abate by
May 10, 2016
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.     a: On 28 February, 2016 the employer did not develop and utilize a procedure to control pneumatic energy associated with gates for the number 5 scale on blending tower.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7000

1910.147 C06 I B

Other-than-serious 1 instance 5 exposed
Issued
Apr 28, 2016
Abate by
May 10, 2016
Penalty
Initial $0 · Current $7,000
29 CFR 1910.147(c)(6)(i)(B): The periodic inspection of the hazardous energy control program shall be conducted to correct any deviations or inadequacies identified.      a: The employer failed to correct inadequacies in the Lockout/tagout program in that procedures to control the energy controlling pneumatic slide gates was not evaluated and added to Lockout/tagout procedures for the blending tower.
Recent events (2)
  • — I (O) $7000
  • — Z (S) $0

1910.147 C07 I A

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Apr 28, 2016
Abate by
May 10, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control:  (a)   Employees performing servicing and maintenance such as but not limited to troubleshooting equipment to the feed tower including pneumatic tube gates,  were not trained on the specific procedures necessary for energy isolation and control.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 D

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Apr 28, 2016
Abate by
May 10, 2016
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.147(d): Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence:  a: Employees performing servicing and maintenance on the Feed tower pneumatic gates were not required to:  (1)  Know the type and magnitude of the energy, the hazards of the energy to be controlled, and the method or means to control the energy, (2) turn off and shut down the machine (3)  physically locate and operate the energy isolating devices in such a manner as to isolate the machine or equipment from the energy source, (4) affix lockout or tagout devices to each energy isolating device, (5) prior to starting work on machines that have been locked out or tagged out, verify that isolation and deenergization of the machine or equipment have been accomplished.  On February 28, 2016, employee(s) troubleshooting the Feed tower were exposed to the unexpected start up of the equipment.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7000

View CPG International LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341323079.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.