Planned inspection · Health discipline

On , OSHA opened a planned health inspection of VIGOR ALASKA SEWARD, LLC in MILE 7 NASH ROAD, SEWARD, AK 99664 (NAICS 336611). OSHA activity number 341384592.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Vigor Alaska Seward, LLC for free Get an email when a new federal OSHA severe-injury report for Vigor Alaska Seward, LLC is published. One employer, no account, unsubscribe in one click.
Site address
MILE 7 NASH ROAD
City
SEWARD
State
AK
ZIP
99664
Mailing
MILE 7 NASH ROAD, SEWARD, AK 99664
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336611
Employees
40
Ownership type
Private (A)

4 citations on file for this inspection.

1910.219 C02 I

Serious Gravity 5 2 instances 1 exposed
Issued
May 10, 2016
Abate by
Jun 8, 2016
Penalty
Initial $3,400 · Current $2,380 Reduced
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting:   (a)  Machine Shop:  On or about April 4, 2016 and at times prior thereto, the horizontal transmission shaft operating five (5) feet above the floor surface on the Cincinnati Bickford "The Super Service Radial" Drill Press (ID#003674) was not guarded.  This condition exposed employees to caught-in hazards.   (b)  Machine Shop:  The horizontal transmission shaft operating 30 inches above the floor surface on the G&L Horizontal Mill was not guarded.  This condition exposed employees to caught-in hazards.   General Industry standard applicable to shipyard employment.
Recent events (2)
  • · I (S) $2380
  • · Z (S) $3400

1910.219 C03

Serious Gravity 5 1 instance 1 exposed
Issued
May 10, 2016
Abate by
Jun 8, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.219(c)(3): Vertical or inclined shafting seven -7 feet or less from floor or working platform was not enclosed with stationary casing:   Machine Shop:  On or about April 4, 2016  and at times prior thereto, the vertical transmission shaft operating 30 inches above the floor surface, 32 diagonal inches from the controls, and 20 inches on the G&L Horizontal Mill was not guarded.  This condition exposed employees to caught-in hazards.  General Industry standard applicable to shipyard employment.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.213 I01

Serious Gravity 5 1 instance 1 exposed
Issued
May 10, 2016
Abate by
Jun 8, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.213(i)(1): Non-working portion(s) of the blade of bandsaw(s) were not enclosed or guarded:  Fab Shop:  On or about April 4, 2016 and at times prior thereto, a minimum 10 inches of the non-working portion of the blade on the Powermatic Model No. 143, Serial No. 8643153 band saw was not guarded or enclosed.  This condition exposed employees to struck-by hazards.  General Industry Standard applicable to Shipyard employment.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.253 B04 III

Other-than-serious 1 instance 4 exposed
Issued
May 10, 2016
Abate by
Jun 8, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:   Machine Shop:  On or about April 4, 2016 and at times prior there to, two (2) oxygen cylinders were stored 42 inches away from two (2) reserve cylinders of acetylene.  This condition exposed employees to smoke-inhalation hazards from rapid acceleration of fire.     General Industry Standard applicable to Shipyard work.
Recent events (2)