HARTFORD, CT —
OSHA Inspection: ELG UTICA ALLOYS (HARTFORD), INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ELG UTICA ALLOYS (HARTFORD), INC. in 239 WEST SERVICE ROAD, HARTFORD, CT 06120 (NAICS 423930). OSHA activity number 341425940.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ELG UTICA ALLOYS (HARTFORD), INC.
- Site address
- 239 WEST SERVICE ROAD
- City
- HARTFORD
- State
- CT
- ZIP
- 06120
- Mailing
- 239 WEST SERVICE ROAD, HARTFORD, CT 06120
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423930
- Employees
- 98
- Ownership type
- A
Citations
26 citations on file for this inspection.
5(a)(1)
- Issued
- Oct 6, 2016
- Abate by
- Sep 30, 2017
- Penalty
- Initial $6,236 · Current $3,742 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fire and explosion hazards posed by the combustible metal dust: A. Solids, Rotary Blast Machines: On, or about, April 25, 2016, dust collection systems provided on the following machines that generated combustible titanium dust were located inside of the building and recirculated the discharge air into the building: 1. Pangborn 1. 2. Pangborn 2. B. Solids, Manual Blast Booth: On, or about, April 25, 2016, the media dust collection system provided for the manual abrasive blasting booth that generated combustible titanium dust was not provided with explosion protection. Spark detection along with either a suppression system or diversion equipment was not provided on the duct that led from the booth to the dust collector. Also, the use of a straight inlet duct without any taper was not in accordance with good engineering practices for the design of ventilation systems.
Recent events (2)
- — I (S) $3741.6
- — Z (S) $6236
1910.22 A01
- Issued
- Oct 6, 2016
- Abate by
- Nov 25, 2016
- Penalty
- Initial $4,988 · Current $2,993 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition: Plant: On, or about, April 23, 2016, combustible dust generated from processing titanium scrap had accumulated on building surfaces. The company had not developed and implemented housekeeping procedures that included regular inspection and cleaning schedules.
Recent events (2)
- — I (S) $2992.8
- — Z (S) $4988
1910.157 G04
- Issued
- Oct 6, 2016
- Abate by
- Nov 25, 2016
- Penalty
- Initial $6,236 · Current $3,742 Reduced
General-duty citation text
29 CFR 1910.157(g)(4): Employees who have been designated to use fire fighting equipment as a part of the emergency action plan were not provided training in the use of appropriate equipment upon initial assignment and at least annually thereafter: Solids: On, or about, April 23, 2016, employees who were expected to use portable fire extinguishers had not been provided with training since November 14, 2012. Several employees used portable fire extinguishers to extinguish a titanium dust fire and had not been trained regarding the limitations of portable fire extinguishers and were not clear on the extent of the response that could be safely conducted in the absence of specialized training and protective gear.
Recent events (2)
- — I (S) $3741.6
- — Z (S) $6236
1910.23 C01
- Issued
- Jul 12, 2016
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: Solids, Fragmetizer: On, or about, May 2, 2016, a guardrail was not provided on the elevated work platform under the in-feed conveyor.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1910.27 B01 II
- Issued
- Jul 12, 2016
- Penalty
- Initial $2,100 · Current $1,260 Reduced
General-duty citation text
29 CFR 1910.27(b)(1)(ii): The distance between rungs exceeded 12 inches and were not uniform throughout the ladder: Solids: On, or about, May 2, 2016, the access ladder provided on the MetFinn shot blasting unit did not have uniform rung spacing.
Recent events (2)
- — I (S) $1260
- — Z (S) $2100
1910.151 C
- Issued
- Jul 12, 2016
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: Wash Tank Area: On, or about, May 17, 2016, an eyewash was not provided where employees periodically replaced totes that contained Mirage MM Additive 2C, a corrosive liquid.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1910.178 A05
- Issued
- Jul 12, 2016
- Penalty
- Initial $2,100 · Current $1,260 Reduced
General-duty citation text
29 CFR 1910.178(a)(5): The powered industrial truck was equipped with front-end attachments other than factory installed attachments, however the employer did not request that the truck be marked to identify the attachments and show the approximate weight of the truck and attachment combination at maximum elevation with load laterally centered: Plant: On, or about, May 24, 2016, the following forktrucks were provided with front end attachments that were not listed on the identification plates: A. Hyster L60. B. Hyster FL61.
Recent events (2)
- — I (S) $1260
- — Z (S) $2100
1910.178 P01
- Issued
- Jul 12, 2016
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s): Plant: On, or about, May 24, 2016, the following forktrucks were in need of repair: A. Hyster L60: The emergency brake did not hold and the forktruck was emitting an excessive amount of carbon monoxide. B. CAT5156: The emergency brake did not hold. C. Hyster FL61: The emergency brake did not hold.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1910.184 E03 I
- Issued
- Jul 12, 2016
- Penalty
- Initial $2,100 · Current $1,260 Reduced
General-duty citation text
29 CFR 1910.184(e)(3)(i): A thorough periodic inspection of alloy steel chain slings was not made on a regular basis and/or were done at intervals greater than once every 12 months: Maintenance Shop: On, or about, May 24, 2016, chain alloy slings used to perform maintenance work were not provided with documented, periodic inspections.
Recent events (2)
- — I (S) $1260
- — Z (S) $2100
1910.212 A01
- Issued
- Jul 12, 2016
- Penalty
- Initial $4,900 · Current $2,940 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by rotating parts, shear points and the unused portion of a blade: A. Solids: On, or about, May 2, 2016, the perforated metal cover used to prevent access to the shot reclamation screw conveyor located in the Manual Blast booth was not secured. It was held down with a block of metal. B. Solids: On, or about, January 25, 2016, the restraint device provided on the Blue Genesco alligator shear was not adjusted to ensure that the operator's fingers could clear the hold-down device. C. Solids: On, or about, April 6, 2016, the restraint device provided on the Logemann Brothers alligator shear, serial number 1154, were adjusted to allow the operators fingertips to reach the shear blade. D. Solids: On, or about, May 2, 2016, the unused portion of the blade on the Chenlong horizontal band saw was not provided with a guard. E. Solids: On, or about, May 2, 2016, one of the restraint devices provided on the Black Genesco alligator shear, Stock #16704, North, allowed the operators fingers to reach the hold-down. F. Solids: On, or about, April 22, 2016, the barrier guard provided on the HTC ten foot shear allowed access to the shear blade.
Recent events (2)
- — I (S) $2940
- — Z (S) $4900
1910.219 C04 I
- Issued
- Jul 12, 2016
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft: Solids, Manual Blast Booth: On, or about, May 2, 2016, the idler shaft ends for the media elevator projected outside the elevator enclosure and were not guarded. The shaft did not present a smooth edge due to the presence of a keyway.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1910.219 F03
- Issued
- Jul 12, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed: Solids, Manual Blast Booth: On, or about, May 2, 2016, the chain and sprocket drive provided for the media elevator was accessible on the side of the guard enclosure.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.244 A02 VI A
- Issued
- Jul 12, 2016
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.244(a)(2)(vi)(a): Each jack used constantly or intermittently at a single locality was not thoroughly inspected at least once every six months: Maintenance Shop: On, or about, May 24, 2016, pumps and jacks used by maintenance staff to maintain equipment in the plant were not subject to regular inspections.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1910.253 B04 III
- Issued
- Jul 12, 2016
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one half hour: Solids: On, or about, May 2, 2016, an oxygen cylinder in storage was located within 20 feet of fuel gas in that: A. The oxygen cylinder was stored on a cart with an acetylene cylinder. B. The cart containing the oxygen cylinder was stored three feet from a propylene cylinder used in the torch cutting booth.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1910.303 B07 I
- Issued
- Jul 12, 2016
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment: A. Compressor Room: On, or about, May 17, 2016, covers had not been provided on electrical raceway that included wiring for the compressors. B. Solids, Location 18-4: On, or about, May 17, 2016, openings left in Panel B-13, a Cutler-Hammer panelboard, were covered with green duct tape. C. NAS: On, or about, May 17, 2016, two Cutler-Hammer panelboards, labeled as C1 and C2, had openings that were not covered by blanks or plates.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1910.303 G01 I A
- Issued
- Jul 12, 2016
- Abate by
- Aug 26, 2016
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(i)(A): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the depth of the working space in the direction of access to live parts (as measured from the live parts where they were exposed or from the enclosure front or opening where they were enclosed) was less than indicated in Table S-1 of Subpart S of Part 1910: Area near Compressor Room: On, or about, May 17, 2016, sufficient working space was not provided for Panel B-8, a Cutler-Hammer 480/277 volt panelboard.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1910.305 G01 IV A
- Issued
- Jul 12, 2016
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: Maintenance Shop: On, or about, May 24, 2016, a water cooler was energized by an extension cord assembly that was run behind equipment and fastened to a chain link fence.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1910.305 G01 IV D
- Issued
- Jul 12, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords and cables were used where attached to building surfaces: Solids, Area Outside of Fragmetizer: Bus Drop Cable was secured to the wall to energize a GE panelboard and a welding receptacle energized by the GE panelboard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.332 B01
- Issued
- Jul 12, 2016
- Abate by
- Aug 26, 2016
- Penalty
- Initial $4,900 · Current $2,940 Reduced
General-duty citation text
29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments: Plant: On, or about, May 24, 2016, maintenance personnel had not been trained regarding what work practices and protective equipment was required to protect them against electric shock, arc flash and arc blast hazards while performing live electrical work, live trouble-shooting and verifying whether or not electrical equipment was properly de-energized.
Recent events (2)
- — I (S) $2940
- — Z (S) $4900
1910.335 A01 I
- Issued
- Jul 12, 2016
- Abate by
- Aug 26, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not provided with electrical protective equipment that was appropriate for the specific parts of the body that needed to be protected and for the work being performed: Plant: On, or about, May 24, 2016, personal protective equipment such as, but not limited to, voltage rated gloves, fire resistive clothing, face shields, face shields, hard hats and hearing protection were not provided to employees who performed live electrical work, including trouble-shooting, or who verified that electrical equipment was properly de-energized.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.334 A02 II
- Issued
- Jul 12, 2016
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service: Lab: On, or about, May 17, 2016, the outer insulation had melted on the power cord for a magnetic base light fixture used at the blue vacuum furnace. The damaged cord had been wrapped in electrical tape.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1910.1200 H03 II
- Issued
- Jul 12, 2016
- Abate by
- Aug 26, 2016
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.1200(h)(3)(ii): Employee training did not include the physical and health hazards of the chemicals in the work area: Plant: On, or about, April 25, 2016, the company had not provided training and information to employees regarding the hazards associated with combustible dusts.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1910.110 B06 VI
- Issued
- Jul 12, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.110(b)(6)(vi): Readily ignitable material such as weeds and long dry grass were not removed within 10 feet of any container. On, or about, May 24, in the following locations, weeds had grown around or inside of propane tank enclosures: A. North Storage Area. B. South Storage Area.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.146 C02
- Issued
- Jul 12, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(c)(2): The employer did not inform exposed employees, by posting danger signs or by any other equally effective means, of the existence and location of and the danger posed by the permit spaces: On, or about, May 17, 2017, in the following locations, signs or placards identified the follows spaces as permit required confined spaces had not been provided: A. Wash Lines: Holding tank. B. Waste Water Treatement Area: Process tanks.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.147 C06 I
- Issued
- Jul 12, 2016
- Abate by
- Aug 26, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: Plant: On, or about, May 24, 2016, the company had not conducted an annual review of the lockout procedures provided for equipment in the plant.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.178 A06
- Issued
- Jul 12, 2016
- Abate by
- Aug 26, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(a)(6): The employer did not ensure that all nameplates or markings were not maintained in a legible condition: Plant: On, or about, May 24, 2016, the identification plate provided on the CAT FL5616 forktruck was burned or similarly damaged and was no longer legible.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at ELG Utica Alloys (Hartford), INC.
View ELG Utica Alloys (Hartford), INC.'s full OSHA safety record →
More inspections in this industry (NAICS 423930)
More inspections in CT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341425940.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.