Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ELG UTICA ALLOYS (HARTFORD), INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of ELG UTICA ALLOYS (HARTFORD), INC. in 239 WEST SERVICE ROAD, HARTFORD, CT 06120 (NAICS 423930). OSHA activity number 341554582.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ELG Utica Alloys (Hartford), INC. — free Get an email when a new federal OSHA severe-injury report for ELG Utica Alloys (Hartford), INC. is published. One employer, no account, unsubscribe in one click.
Site address
239 WEST SERVICE ROAD
City
HARTFORD
State
CT
ZIP
06120
Mailing
239 WEST SERVICE ROAD, HARTFORD, CT 06120
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423930
Employees
98
Ownership type
A

8 citations on file for this inspection.

1910.95 D01

Other-than-serious 4 instances 680 exposed
Issued
Sep 30, 2016
Abate by
Nov 18, 2016
Penalty
Initial $6,236 · Current $3,742 Reduced
29 CFR 1910.95(d)(1): When information indicated that any employee's exposure equaled or exceed the 8-hour time-weighted average of 85 decibels, the employer did not develop and implement a monitoring program:    Shop Area    On or about 6/28/16, the employer did not implement a monitoring program for employees whose exposure exceeded the eight hour TWA of 85 dBA.  Employees working in the shop area on the following tasks had 8-hour-TWA noise exposures over 85 dBA when monitored for hearing conservation:       a. torch cutting:  90.9 dBA  b. washer: 86.3 dBA  c. gritblaster : 88.6 dBA  d. mechanical shears: 89 dBA
Recent events (2)
  • — I (O) $3741.6
  • — Z (S) $6236

1910.95 G08 II B

Serious Gravity 10 4 instances 4 exposed
Issued
Sep 30, 2016
Abate by
Nov 18, 2016
Penalty
Initial $8,730 · Current $5,238 Reduced
29 CFR 1910.95(g)(8)(ii)(B): Unless a physician determines that the standard threshold shift is not work-related or aggravated by occupational noise exposure, the employer did not ensure, when a standard threshold shift occurs, that for employees already using hearing protectors, employees be refitted and retrained in the use of hearing protectors and provided with hearing protectors offering greater attenuation if necessary:    Shop Area        On or about 6/16/16, employees had experienced standard threshold shifts on their last audiogram. The employer was notified of the shift and the notification provided recommended re-test.  The employer failed to provide a re-test, re-fit for hearing protectors, or retraining to those employees affected.
Recent events (2)
  • — I (S) $5238
  • — Z (S) $8730

1910.95 I02 II B

Serious Gravity 10 68 instances 68 exposed
Issued
Sep 30, 2016
Abate by
Nov 18, 2016
Penalty
Initial $8,730 · Current $0 Reduced
29 CFR 1910.95(i)(2)(ii)(B): The employer did not ensure that hearing protectors are worn by any employee who is exposed to an 8-hour time-weighted average of 85 decibels or greater and has experienced a standard threshold shift:    Shop Area    On or about 6/28/16, the employer did not require the use of hearing protectors by employees who worked in areas where the 8-hr TWA exceeded 85 dBA or those who experienced a standard threshold shift in their hearing on the employer provided audiogram.
Recent events (2)
  • — I (S) $0
  • — Z (S) $8730

1910.95 I03

Other-than-serious 1 instance 68 exposed
Issued
Sep 30, 2016
Abate by
Nov 18, 2016
Penalty
Initial $4,988 · Current $2,993 Reduced
29 CFR 1910.95(i)(3): Employees were not given the opportunity to select their hearing protectors from a variety of suitable hearing protectors provided by the employer:    Shop area    On or about 6/28/16, employees were not provided a selection of hearing protectors from which to choose.
Recent events (2)
  • — I (O) $2992.8
  • — Z (S) $4988

1910.134 F02

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 30, 2016
Abate by
Nov 18, 2016
Penalty
Initial $4,988 · Current $2,993 Reduced
29 CFR 1910.134(f)(2): Employee(s) using a tight-fitting facepiece respirator were not annually fit tested:  Torch cutting booth;  On or about 6/28/16, an employee torch cutting titanium alloy had not been fit tested for his half-face, tight fitting air purifying respirator since 1/24/14.  The task was monitored that day and resulted in an over exposure for vanadium.
Recent events (2)
  • — I (S) $2992.8
  • — Z (S) $4988

1910.1000 A

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 30, 2016
Abate by
Nov 18, 2016
Penalty
Initial $4,988 · Current $2,993 Reduced
29 CFR 1910.1000(a): Employee(s) were exposed to an airborne concentration of vanadium listed in Table Z-1, Limits for Air Contaminants, in excess of the PEL without regards to respiratory protection.  Torch cutting booth;  On or about 6/28/16, an employee working in the torch cutting booth and cutting titanium alloy pieces was exposed to vanadium at a time-weighted average of 0.14 mg/m3, which is 140% of the permissible exposure limit of 0.1 mg/m3. The employee was wearing a half-face respirator with a P100 filter, however the employee had not been fit tested since 1/24/14.
Recent events (2)
  • — I (S) $2992.8
  • — Z (S) $4988

1910.1000 E

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 30, 2016
Abate by
Nov 18, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1000(e): Feasible administrative or engineering controls were not determined and implemented to achieve compliance with the limits prescribed in 29 CFR 1910.1000(a) through (d):  Torch Cutting Booth;  On or about 6/28/16, an employee torch cutting titanium alloy was exposed to vanadium at a time-weighted average of 0.14 mg/m3, which is 140% over the permissible exposure limit.  The task was performed in an exhausted booth, however the engineering and administrative controls used did not maintain employee exposure below the PEL, without use of respiratory protection.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.95 G05 IV

Deleted Other-than-serious 1 instance 68 exposed
Issued
Sep 30, 2016
Abate by
Nov 18, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.95(g)(5)(iv): The employer did not notify employees of the need to avoid high levels of non-occupational noise exposure during the 14-hour period immediately preceding the audiometric examination:  Shop area  On or about 6/28/16, employees had not been instructed to avoid high levels of noise exposure for 14 hours prior to their annual audiograms.  A truck came to the site and employees worked in the shop until it was their turn to go out for their audiograms.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View ELG Utica Alloys (Hartford), INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341554582.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.