Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ELG UTICA ALLOYS (HARTFORD), INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ELG UTICA ALLOYS (HARTFORD), INC. in 239 WEST SERVICE ROAD, HARTFORD, CT 06120 (NAICS 423930). OSHA activity number 347579799.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ELG Utica Alloys (Hartford), INC. — free Get an email when a new federal OSHA severe-injury report for ELG Utica Alloys (Hartford), INC. is published. One employer, no account, unsubscribe in one click.
Site address
239 WEST SERVICE ROAD
City
HARTFORD
State
CT
ZIP
06120
Mailing
239 WEST SERVICE ROAD, HARTFORD, CT 06120
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423930
Employees
148
Ownership type
A

6 citations on file for this inspection.

1910.176 B

Serious Gravity 1 3 instances 148 exposed
Issued
Nov 12, 2024
Abate by
Dec 31, 2024
Penalty
Initial $5,288 · Current $3,000 Reduced
29 CFR  1910.176(b): Material stored in tiers was not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse:  Warehouse/ Turnings area - South wall. On or about June 26, 2024, Supersacks, IBC totes, 55-gallon drums, cardboard boxes, pallets, plastic totes, and other containers enclosing a variety of metal turnings, fluids, and other materials were stacked above six feet in height along walkways and exit accesses and were not stabilized or secured against sliding or collapse.
Recent events (3)
  • — F (S) $3000
  • — C (S) $5288
  • — Z (S) $5288

1910.212 A01

Serious Gravity 5 3 instances 148 exposed
Issued
Nov 12, 2024
Abate by
Dec 31, 2024
Penalty
Initial $7,052 · Current $5,000 Reduced
29 CFR  1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by rotating parts.  Crusher area, Washer area. On or about June 26, 2024: a) The elevated augers on washers #1 and #3 were unguarded. b) The end bearing on crusher #3 was unguarded.
Recent events (3)
  • — F (S) $5000
  • — C (S) $7052
  • — Z (S) $7052

1910.157 C01

Other-than-serious 2 instances 148 exposed
Issued
Nov 12, 2024
Abate by
Dec 31, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  Warehouse/ Turnings area. On or about June 26, 2024 the following conditions were observed: a) Southeast column. Two extinguishers (1-A and 1-ABC) were not mounted on or otherwise secured to a marked column, creating a potential hazard if moved or knocked over. b) West column - loading dock. An extinguisher was mounted within the webbing of a structural column, but was not identified in order to be readily accessible.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.157 E03

Other-than-serious 5 instances 148 exposed
Issued
Nov 12, 2024
Abate by
Dec 31, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check:  Warehouse/ Turnings area, Crusher area, Washer area. On or about June 26, 2024, four Class ABC extinguishers and one Class A extinguisher had not been subjected to an annual maintenance check in two years.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.22 A02

Other-than-serious Gravity 5 1 instance 148 exposed
Issued
Nov 12, 2024
Abate by
Dec 31, 2024
Penalty
Initial $7,052 · Current $7,052
29 CFR  1910.22(a)(2): The employer did not ensure that the  floor of each workroom is maintained in a clean and, to the extent feasible, in a dry condition. The employer did not ensure that when wet processes are used, drainage is maintained and, to the extent feasible, dry standing places, such as false floors, platforms, and mats are provided.  Warehouse/ Turnings area - East wall. On or about June 26, 2024 the exit access floor was wet and covered with an unknown slick substance. Exit access was not possible without the risk of slipping.
Recent events (3)
  • — F (O) $7052
  • — C (S) $7052
  • — Z (S) $7052

1910.37 B04

Other-than-serious 1 instance 148 exposed
Issued
Nov 12, 2024
Abate by
Dec 31, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.37(b)(4): Signs were not posted along the exit access indicating the direction of travel to the nearest exit and exit discharge when the direction of travel to the exit or exit discharge was not immediately apparent:  Warehouse/ Turnings area - Southeast wall. On or about June 26, 2024 the exit door located at the East end of the South wall was obstructed from view by IBC totes, Supersacks, and various other containers. No other signage was visible along the exit access.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

View ELG Utica Alloys (Hartford), INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347579799.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.