Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BIA-WESTERN REGION

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of BIA-WESTERN REGION in PAPAGO AGENCY ADMINISTRATIVE OFFICE, CIRCLE DRIVE, BLDG 49, SELLS, AZ 85634 (NAICS 561210). OSHA activity number 341451102.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bia-Western Region — free Get an email when a new federal OSHA severe-injury report for Bia-Western Region is published. One employer, no account, unsubscribe in one click.
Establishment
BIA-WESTERN REGION
Site address
PAPAGO AGENCY ADMINISTRATIVE OFFICE, CIRCLE DRIVE, BLDG 49
City
SELLS
State
AZ
ZIP
85634
Mailing
REGIONAL OFFICE 2600 N. CENTRAL AVENUE, 4TH FLOOR MAILROOM, PHOENIX, AZ 85004
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561210
Employees
11
Ownership type
D

8 citations on file for this inspection.

1910.132 D01

Serious Gravity 5 1 instance 2 exposed
Issued
May 18, 2016
Abate by
Jun 22, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE):    (a) Administrative Office Building 49: On or about May 3, 2016 and at times prior thereto, a hazard assessment was not performed to identify personal protective equipment necessary to protect maintenance workers from asbestos-containing material when entering areas such as, but not limited to, the mechanical room, the boiler room and crawlspaces.
Recent events (2)
  • — Z $0
  • — Z (S) $0

1910.1001 D02 I

Serious Gravity 5 1 instance 2 exposed
Issued
May 18, 2016
Abate by
Jul 6, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1001(d)(2)(i): The employer did not perform initial monitoring of employees who were, or might reasonably be expected to be exposed to airborne concentrations at or above the 8-hour TWA and/or excursion limits:  (a) Administrative Office Building 49: On or about May 3, 2016 and at times prior thereto, initial monitoring was not performed for maintenance workers who perform work in asbestos-containing areas such as, but not limited to, the mechanical room and boiler room which have asbestos-containing thermal system insulation (TSI) and crawlspaces which have asbestos-contaminated soil.
Recent events (2)
  • — Z $0
  • — Z (S) $0

1910.1001 J04 IV

Serious Gravity 5 1 instance 2 exposed
Issued
May 18, 2016
Abate by
Jun 7, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1001(j)(4)(iv): At the entrance to mechanical rooms/areas in which employees reasonably can be expected to enter and which contain asbestos containing material (ACM) and/or presumed asbestos containing material (PACM), the building owner did not post signs which identify the material which is present, its location, and appropriate work practices which, if followed, will ensure that ACM and/or PACM will not be disturbed:  (a) Administrative Office Building 49: On or about May 3, 2016 and at times prior thereto, signs were not posted at the entrance to the mechanical room, boiler room and crawlspaces. These areas have asbestos-containing thermal system insulation (TSI) and/or asbestos-contaminated soil.
Recent events (1)
  • — Z (S) $0

1910.1001 J05 I

Serious Gravity 5 1 instance 2 exposed
Issued
May 18, 2016
Abate by
Jun 7, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1001(j)(5)(i): Labels or signs were not affixed or posted to previously installed and identified ACM and/or PACM so that employees will be notified of what materials contain ACM and/or PACM:  (a) Administrative Office Building 49: On or about May 3, 2016 and at times prior thereto, labels or signs were not affixed or posted to previously identified asbestos-containing material (ACM) or presumed asbestos-containing material (PACM) such as, but not limited to, asbestos-containing thermal system insulation (TSI).
Recent events (2)
  • — Z $0
  • — Z (S) $0

1910.1001 J07 I

Serious Gravity 5 1 instance 2 exposed
Issued
May 18, 2016
Abate by
Jun 7, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1001(j)(7)(i): The employer did not train each employee who was exposed to airborne concentrations of asbestos at or above the 8-hour TWA and/or excursion permissible exposure limit(s) in accordance with the requirements of this section:   (a) Administrative Office Building 49: On or about May 3, 2016 and at times prior thereto, maintenance employees were not trained in accordance with requirements of OSHA's asbestos standard.
Recent events (2)
  • — Z $0
  • — Z (S) $0

1910.38 A

Repeat 1 instance 11 exposed
Issued
May 18, 2016
Abate by
Jun 7, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.38(a): The employer did not establish a written emergency evacuation plan for employees expected to evacuate in the event of a fire or other emergency:  a) Administrative Office Building 49: On or about May 3, 2016 and at times prior thereto, a site-specific written emergency evacuation plan was not established for the facility.   The BIA was previously cited for a violation of this occupational safety and health standard which was contained in OSHA inspection number 1056009 citation number 1, item number 1A and was affirmed as a final order on March 22, 2016, with respect to a workplace located at the Division of Transportation, Bldg. 40, Blue Canyon Rd., Fort Defiance, AZ 86504.
Recent events (1)
  • — Z (R) $0

1904.32 A02

Other-than-serious 1 instance 11 exposed
Issued
May 18, 2016
Abate by
Jun 7, 2016
Penalty
Initial $0 · Current $0
29 CFR 1904.32(a)(2): The employer did not create an annual summary of injuries and illnesses recorded on the OSHA log:  (a) Administrative Office Building 49: A site-specific annual summary of injuries and illnesses (OSHA form 300A) was not created for calendar year 2015.
Recent events (1)
  • — Z (O) $0

1910.157 E03

Other-than-serious 1 instance 11 exposed
Issued
May 18, 2016
Abate by
Jun 7, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check:  (a) Administrative Office Building 49: On or about May 3, 2016, annual maintenance checks on portable fire extinguishers were not conducted. Portable fire extinguishers are located throughout the facility and were last inspected November 2014.
Recent events (1)
  • — Z (O) $0

View Bia-Western Region's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341451102.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.