Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AMERICAN/JEBCO CORPORATION

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of AMERICAN/JEBCO CORPORATION in 11330 WEST MELROSE AVE., FRANKLIN PARK, IL 60131 (NAICS 339993). OSHA activity number 341464626.

Watch American/Jebco Corporation — free Get an email when a new federal OSHA severe-injury report for American/Jebco Corporation is published. One employer, no account, unsubscribe in one click.
Site address
11330 WEST MELROSE AVE.
City
FRANKLIN PARK
State
IL
ZIP
60131
Mailing
11330 WEST MELROSE AVE., FRANKLIN PARK, IL 60131
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
339993
Employees
50
Ownership type
A

8 citations on file for this inspection.

1910.22 A02

Serious Gravity 1 2 instances 2 exposed
Issued
Aug 1, 2016
Abate by
Aug 25, 2016
Penalty
Initial $2,100 · Current $1,071 Reduced
29 CFR 1910.22(a)(2): Floor(s) of workroom(s) were not maintained, so far as possible, in a dry condition:       a) Cold Header Area - On May 10, 2016, near machine National 205, there was oil accumulation on the floor exposing employees to a slip and fall hazard.      b) Cold Header Area - On May 10, 2016, near by the operator stand on Machine #118, there was oil accumulation on the floor exposing employees to a slip and fall hazard.
Recent events (2)
  • — I (S) $1071
  • — Z (S) $2100

1910.106 E02 II

Serious Gravity 1 1 instance 1 exposed
Issued
Aug 1, 2016
Abate by
Aug 25, 2016
Penalty
Initial $2,100 · Current $1,071 Reduced
29 CFR 1910.106(e)(2)(ii): Flammable liquids were not stored in tanks or closed containers:    a) Cold Header Area - On May 10, 2016, the employer did not ensure that flammable liquids near Machine #33, were stored in closed containers.
Recent events (2)
  • — I (S) $1071
  • — Z (S) $2100

1910.147 C01

Serious Gravity 5 1 instance 5 exposed
Issued
Aug 1, 2016
Abate by
Aug 25, 2016
Penalty
Initial $2,800 · Current $1,428 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative.    a) Throughout Plant - On May 10, 2016, the employer did not establish an energy control procedure (lockout/tagout program) and did not provide training on the energy control procedure to ensure all required elements of the procedure were understood by employees and the knowledge and skills required for the safe application, usage and removal of energy controls were acquired by employees performing servicing and maintenance on a machine or equipment, such as, Cold Header Machines.
Recent events (2)
  • — I (S) $1428
  • — Z (S) $2800

1910.212 A01

Serious Gravity 5 2 instances 2 exposed
Issued
Aug 1, 2016
Abate by
Aug 25, 2016
Penalty
Initial $3,500 · Current $1,802 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding were not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:       a) Cold Heading Area - On May 10, 2016, the National #204, Cold Header Machine was not equipped with an enclosure guard to protect employees from the rotating parts.    b) Cold Heading Area - On May 10, 2016, the National #205, Cold Header Machine had a guard that was not completely enclosed to protect employees from the rotating parts.
Recent events (2)
  • — I (S) $1802
  • — Z (S) $3500

1910.305 B01 I

Serious Gravity 5 3 instances 1 exposed
Issued
Aug 1, 2016
Abate by
Aug 25, 2016
Penalty
Initial $2,800 · Current $1,428 Reduced
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasion, and openings through which conductors enter were not effectively closed:    a) Cold Header Area - On May 10, 2016, the employer did not ensure that the door on the electrical panel of the National #16, Cold Header Machine was closed.      b) Cold Header Area - On May 10, 2016, the employer did not ensure that the door on the electrical panel of the RMG, model #46-6546-87, serial #96083895, Cold Header Machine was closed.     c) Cold Header Area - On May 10, 2016, the employer did not ensure that the door on the electrical panel of the RMG #7, Cold Header Machine was closed.
Recent events (2)
  • — I (S) $1428
  • — Z (S) $2800

1910.1200 E01

Other-than-serious 1 instance 1 exposed
Issued
Aug 1, 2016
Abate by
Sep 9, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:     a) Cold Header Area - The employer did not develop or implement a written hazard communication program, in accordance with 29 CFR 1910.1200(e)(1) that would describe or include at least the following:    1) Requirement for labeling of containers of hazardous chemicals;  2) Safety data sheet availability;  3) Training of employees;  4) A complete list of hazardous chemicals known to be present in the workplace;  5) Methods to inform employees of the hazards on non-routine tasks; and  6) Methods to inform other employer(s) of material safety data sheet availability; the labeling system and any precautionary measures to protect employees.    Employee(s) were exposed to hazardous chemicals, including Perchem 1000, (Distillates (petroleum), hydrotreated light), Perdraw 7308, (Limestone, Distillates (petroleum), hydrotreated heavy paraffinic, Alkanes, chloro), Perkut 349, (Distillates (petroleum), hydrotreated heavy naphthenic).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 F06 II

Other-than-serious 1 instance 1 exposed
Issued
Aug 1, 2016
Abate by
Aug 25, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(6)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged, or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical(s) contained therein:     a) Cold Header Area - The employer did not ensure that each container of hazardous chemicals in the workplace, including buckets of solvents (Perchem 1000, (Distillates (petroleum), hydrotreated light), Perdraw 7308, (Limestone, Distillates (petroleum), hydrotreated heavy paraffinic, Alkanes, chloro), Perkut 349, (Distillates (petroleum), hydrotreated heavy naphthenic) was labeled with the identity of the chemical and the information regarding physical and health hazards of the hazardous chemicals contained therein.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 H01

Other-than-serious 1 instance 1 exposed
Issued
Aug 1, 2016
Abate by
Sep 9, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided information and training as specified in 29 CFR 1910.1200(h)(1) and (2) on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard was introduced into their work area:       a) The employer did not provide information and training to employees exposed to hazardous chemicals, including Perdraw 7308, (Limestone, Distillates (petroleum), hydrotreated heavy paraffinic, Alkanes, chloro), Perkut 349, (Distillates (petroleum), hydrotreated heavy naphthenic).        b) The employer did not provide training to employees by December 1, 2013 on the revised Safety Data Sheet format and content, as well as the new labeling elements, as required by the revised 2012 hazard communication standard, 29 CFR 1910.1200.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View American/Jebco Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341464626.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.