BROOKVILLE, PA —
OSHA Inspection: HUMPHREY CHARCOAL CORPORATION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of HUMPHREY CHARCOAL CORPORATION in 13760 KNOX DALE ROAD, BROOKVILLE, PA 15825 (NAICS 324199). OSHA activity number 341505238.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HUMPHREY CHARCOAL CORPORATION
- Site address
- 13760 KNOX DALE ROAD
- City
- BROOKVILLE
- State
- PA
- ZIP
- 15825
- Mailing
- 13760 KNOX DALE ROAD, BROOKVILLE, PA 15825
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 324199
- Employees
- 13
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.23 D01
- Issued
- Aug 1, 2016
- Abate by
- Sep 26, 2016
- Penalty
- Initial $1,440 · Current $720 Reduced
General-duty citation text
29 CFR 1910.23(d)(1): Every flight of stairs having four or more risers was not be equipped with standard stair railings or standard handrails as specified in paragraphs (d)(1)(i) through (v) of this section: A.) Humphrey Charcoal Corporation - On or about 5/25/16, and at times prior thereto, employees were utilizing a moveable set of stairs to access the loading dock. The stairs did not have a standard stair railing on the left side and the right side railing was damaged. In addition, the railing did not extend to the top of the dock to provide an adequate handhold for the employees. B.) Humphrey Charcoal Corporation - On or about 5/25/16, and at times prior thereto, employees were utilizing a permanent set of stairs to access the loading dock. The stairs did not have a standard stair railing on the right side.
Recent events (2)
- — I (S) $720
- — Z (S) $1440
1910.212 A01
- Issued
- Aug 1, 2016
- Abate by
- Sep 26, 2016
- Penalty
- Initial $3,080 · Current $1,540 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: A.) Humphrey Charcoal Corporation; briquette mill - On or about 5/25/16, and at times prior thereto, moving parts on the briquette mill were not guarded. The unguarded moving parts including but were not limited to the briquette pan. B.) Humphrey Charcoal Corporation; briquette mill - On or about 5/25/16, and at times prior thereto, the end of the conveyor of the briquette mill was not guarded. The condition exposed employees to the nip point created by the belt conveyor.
Recent events (2)
- — I (S) $1540
- — Z (S) $3080
1910.212 A03 III
- Issued
- Aug 1, 2016
- Abate by
- Sep 26, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(3)(iii): Special hand tools for placing and removing material(s) was not provided to permit easy handling of material without the operator placing a hand in the danger zone: A.) Humphrey Charcoal Corporation; briquette mill - On or about 5/25/16, and times prior thereto, employees were reaching into an area near the briquette mill pan to scoop out charcoal mixture onto the conveyor. The employees were not using any types of special tooling to keep their hands out of the moving parts. Moving parts included, but were not limited to, the briquette mill pan.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.304 C02
- Issued
- Aug 1, 2016
- Abate by
- Sep 26, 2016
- Penalty
- Initial $3,080 · Current $1,540 Reduced
General-duty citation text
29 CFR 1910.304(c)(2): Open outside conductors rated 600 volts, nominal, or less did not conform to minimum vertical clearances as specified in paragraphs (c)(2)(i) through (c)(2)(iv) of this section A.) Humphrey Charcoal Corporation; outside break room - On or about 5/25/16, and at times prior thereto, outside wiring that powers various things including, but not limited to the mill, was located less than 10 feet of the ground. The wire connections outside of the break room/ maintenance area were within 7 feet of the ground.
Recent events (2)
- — I (S) $1540
- — Z (S) $3080
1910.219 D01
- Issued
- Aug 1, 2016
- Abate by
- Sep 26, 2016
- Penalty
- Initial $4,400 · Current $2,200 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): A.) Humphrey Charcoal Corporation; weight bagger platform - On or about 5/25/16, and at times prior thereto, employees were exposed to an unguarded belt and pulley system that was 4 feet above the level the work platform. Humphrey Charcoal Corporation was previously cited for a violation of this occupational safety and health standard or its equivalent standard (1910.219(d)(1)), which was contained in OSHA inspection number 916884, citation number 1, item number 5 and was affirmed as a final order on 1/13/14, with respect to a workplace located at 13760 Know Dale Road, Brookville, PA.
Recent events (2)
- — I (R) $2200
- — Z (R) $4400
1910.176 B
- Issued
- Aug 1, 2016
- Abate by
- Sep 26, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.176(b): Material stored in tiers was not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse: A.) Humphrey Charcoal Corporation; loading dock - On or about 5/25/16, and at times prior thereto, pallets were stacked on the loading dock. The stacks were uneven, leaning and not arranged in a neat, orderly manner.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 G01 II
- Issued
- Aug 1, 2016
- Abate by
- Sep 26, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: A.) Humphrey Charcoal Corporation - On or about 5/25/16, and at times prior thereto, the area under 480 volt electrical panels was being used for storage. Items being stored, included, but were not limited to, a pump and an anvil.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Humphrey Charcoal Corporation
View Humphrey Charcoal Corporation's full OSHA safety record →
More inspections in this industry (NAICS 324199)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341505238.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.