Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TROYMILL WOOD PRODUCTS

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of TROYMILL WOOD PRODUCTS in 14550 MADISON ROAD, MIDDLEFIELD, OH 44062 (NAICS 321920). OSHA activity number 341533941.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Troymill Wood Products — free Get an email when a new federal OSHA severe-injury report for Troymill Wood Products is published. One employer, no account, unsubscribe in one click.
Site address
14550 MADISON ROAD
City
MIDDLEFIELD
State
OH
ZIP
44062
Mailing
17055 KINGSMAN ROAD, MIDDLEFIELD, OH 44062
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321920
Employees
10
Ownership type
A

5 citations on file for this inspection.

1910.305 G01 IV A

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 22, 2016
Abate by
Jul 12, 2016
Penalty
Initial $2,380 · Current $1,666 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  a) On or about June 8, 2016, the employer exposed employees to electrical hazards, by utilizing a flexible cord as a substitute for permanent wiring which was used to provide power to the hydraulic solenoid located under the rollers used with the Wirlwind Cut Off Saw, located in Building B.
Recent events (2)
  • — I (S) $1666
  • — Z (S) $2380

1910.305 G02 II

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 22, 2016
Abate by
Jul 12, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap:  On or about June 8, 2016, the employer failed to ensure that flexible cords being used to provide power to the hydraulic solenoid, located under the rollers used with the Wirlwind Cut Off Saw in Building B, were not spliced and used only in continuous length.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 22, 2016
Abate by
Jul 12, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:  On or about June 8, 2016, the employer failed to ensure that the flexible cords ground plug, leading to the hydraulic solenoid, was properly installed with effective strain relief.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.334 A02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 22, 2016
Abate by
Jul 12, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):  On or about June 8, 2016, the employer exposed employees to a damaged flexible cord that was used for the hydraulic solenoid under the rollers used with the Wirlwind Cut Off Saw, located in Building B.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 L04 III

Other-than-serious 1 instance 2 exposed
Issued
Jun 22, 2016
Abate by
Jul 12, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years:  On or about June 8, 2016, the employer failed to ensure that employees who operate the powered industrial vehicles were given an evaluation every three years. The last evaluation given was September 30, 2011.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Troymill Wood Products's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341533941.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.