FORT BUCHANAN, PR —
OSHA Inspection: ARMY AND AIR FORCE EXCHANGE SERVICE - FORT BUCHANAN STORE
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of ARMY AND AIR FORCE EXCHANGE SERVICE - FORT BUCHANAN STORE in 606 N. TERMINAL ROAD, FORT BUCHANAN, PR 00934 (NAICS 452111). OSHA activity number 341540458.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Site address
- 606 N. TERMINAL ROAD
- City
- FORT BUCHANAN
- State
- PR
- ZIP
- 00934
- Mailing
- 606 N. TERMINAL ROAD, FORT BUCHANAN, PR 00934
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 452111
- Employees
- 70
- Ownership type
- D
Citations
6 citations on file for this inspection.
1910.23 E01
- Issued
- Jun 23, 2016
- Abate by
- Jul 13, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(e)(1): Standard railing(s) did not consist of top rail, intermediate rail and/or posts and/or did not have a vertical height of 42 inches (106.7 cm) nominal from upper surface of top rail to floor, platform runway, or ramp level: a. On or about June 10, 2016, at the administrative offices entrance and exit door area, employees were exposed to a 49 inches fall to the ground below when walking on a stairway that lacked a mid-rail and was used as an entrance and exit access to store main building. Note: Certification of abatement must be submitted for this citation item as required by 29 CFR 1903.19(c).
Recent events (1)
- — Z (S) $0
1910.36 G02
- Issued
- Jun 23, 2016
- Abate by
- Jun 29, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points. On or about June 10, 2016, at the receiving Class VI warehouse area, employees working on material handling operations were exposed to a fire hazard when the exit access hallway had various measurements along the pathway as follows: a. 26 1/2 inches wide b. 25 inches wide c. 24 inches wide Note: Certification of abatement is not required for this citation item since it was submitted prior to citation issuance.
Recent events (1)
- — Z (S) $0
1910.305 G02 III
- Issued
- Jun 23, 2016
- Abate by
- Jun 29, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: a. On or about June 10, 2016, at the receiving Class VI area, employees were exposed to an electrical hazard while plugging and unplugging flexible cord with the outer sheeting removed during Crown WP 3035-45 pallet trucks battery charging operation. b. On or about June 10, 2016 at the warehouse area next to cardboard compactor, employees were exposed to an electrical hazard while plugging and unplugging flexible cord with the outer sheeting removed during Crown WP 3035-45 pallet trucks battery charging operation. Note: Certification of abatement is not required for this citation item since it was submitted prior to citation issuance.
Recent events (1)
- — Z (S) $0
1910.1200 E01
- Issued
- Jun 23, 2016
- Abate by
- Jun 29, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: On or about June 10, 2016, at the receiving area, employees were exposed to hazardous products and the employer did not ensure to have their safety data sheets available at the workplace as described in their written hazard communication program procedures during the following warehouse operations: a. Caterpillar forklift gasoline fuel re-filling. b. Replacement of Caterpillar forklift propane (LPG) empty tanks with full tanks. c. Crown pallet trucks battery (sulfuric acid) charging. NOTE: Certification of abatement is not required for this citation item since it was submitted prior to citation issuance.
Recent events (1)
- — Z (S) $0
1910.1200 G01
- Issued
- Jun 23, 2016
- Abate by
- Jun 29, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use On or about June 10, 2016, at the receiving area, employees were exposed to hazardous products and the employer did not ensure that their safety data sheets were available during the following warehouse operations: a. Caterpillar forklift gasoline fuel re-filling. b. Replacement of Caterpillar forklift propane (LPG) empty tanks with full tanks. c. Crown pallet trucks battery (sulfuric acid) charging. NOTE: Certification of abatement is not required for this citation item since it was submitted prior to citation issuance.
Recent events (1)
- — Z (S) $0
1910.305 B01 II
- Issued
- Jun 23, 2016
- Abate by
- Jul 13, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: On or about June 10, 2016, employees were exposed to a possible fire hazard when working near electrical junction boxes with openings as follows: a. At the receiving loading dock area, employees plug and/or unplug lamp on junction box with side opening during loading and/or unloading operations. b. At the mechanical room area, employees work close to junction box with side opening when accessing phone lines panel. Note: Certification of abatement must be submitted for this citation item as required by 29 CFR 1903.19(c).
Recent events (1)
- — Z (O) $0
More inspections at Army and AIR Force Exchange Service - Fort Buchanan Store
View Army and AIR Force Exchange Service - Fort Buchanan Store's full OSHA safety record →
More inspections in this industry (NAICS 452111)
More inspections in PR
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341540458.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.