Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AMNEAL PHARMACEUTICALS, LLC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of AMNEAL PHARMACEUTICALS, LLC. in 209 MCLEAN BLVD., PATERSON, NJ 07504 (NAICS 325412). OSHA activity number 341574796.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Amneal Pharmaceuticals, LLC. — free Get an email when a new federal OSHA severe-injury report for Amneal Pharmaceuticals, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
209 MCLEAN BLVD.
City
PATERSON
State
NJ
ZIP
07504
Mailing
1 NEW ENGLAND AVE., PISCATAWAY, NJ 08854
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325412
Employees
25
Ownership type
A

6 citations on file for this inspection.

1910.37 B02

Serious Gravity 1 1 instance 3 exposed
Issued
Nov 2, 2016
Penalty
Initial $5,345 · Current $5,345
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":  a) Blending area adjacent to Pharmacy Department: A doorway designated as an emergency exit, was missing an exit sign, on or about, 6/28/16.
Recent events (1)
  • — Z (S) $5345

1910.147 C04 I

Serious Gravity 1 1 instance 3 exposed
Issued
Nov 2, 2016
Penalty
Initial $5,345 · Current $5,345
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  a) Blending Department: The employer did not establish written procedures for the V-Shell Blending machine, on or about, 6/23/16.
Recent events (1)
  • — Z (S) $5345

1910.147 C06 I

Serious Gravity 1 1 instance 3 exposed
Issued
Nov 2, 2016
Penalty
Initial $5,345 · Current $5,345
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  a) Blending Department: The employer did not conduct annual periodic inspections of the energy procedures to ensure that affected employees were following establish written procedures for the V-Shell Blending machine, on or about, 6/23/16.
Recent events (1)
  • — Z (S) $5345

1910.147 C07 I

Serious Gravity 1 1 instance 3 exposed
Issued
Nov 2, 2016
Penalty
Initial $5,345 · Current $5,345
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees:  a) Blending Department: The employer did not provide affected employees who service the Ohara V-Shell Blender, with lockout/tagout training, on or about, 6/23/16.
Recent events (1)
  • — Z (S) $5345

1910.305 B01 II

Serious Gravity 1 1 instance 3 exposed
Issued
Nov 2, 2016
Penalty
Initial $5,345 · Current $5,345
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  a) Blending Room: P-132: A junction box used to power control sensors was missing knockouts, on or about, 9/2/16.
Recent events (1)
  • — Z (S) $5345

1910.134 K06

Other-than-serious 1 instance 3 exposed
Issued
Nov 2, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer:  a) Facility: The employer did not provide basic advisory information for employees who voluntary wear N95 dust masks, on or about, 6/23/16.
Recent events (1)
  • — Z (O) $0

View Amneal Pharmaceuticals, LLC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341574796.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.