PROSPECT HEIGHTS, IL —
OSHA Inspection: ELITE EXTERIORS, LLC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ELITE EXTERIORS, LLC. in 79-85 COUNTRY CLUB CT., PROSPECT HEIGHTS, IL 60070 (NAICS 238160). OSHA activity number 341580678.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ELITE EXTERIORS, LLC.
- Site address
- 79-85 COUNTRY CLUB CT.
- City
- PROSPECT HEIGHTS
- State
- IL
- ZIP
- 60070
- Mailing
- 16W328 W. HILLSIDE LANE, BURR RIDGE, IL 60527
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 10
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.501 B13
- Issued
- Jun 29, 2016
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b): a) Lot 79 - On or about June 27, 2016, employees were exposed to the hazard of falling while working from pitched roof surfaces without the benefit of fall protection. b) Lot 85 - On or about June 27, 2016, employees were exposed to the hazard of falling while working from pitched roof surfaces without the benefit of fall protection. No abatement certification or documentation required for this violation.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1926.1053 B01
- Issued
- Jun 29, 2016
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) Lot 79 - On or about June 27, 2016, employees were exposed to the hazard of falling approximately 8 feet where a portable extension ladder did not extend above the landing surface of a roof deck. No abatement certification or documentation required for this violation.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1926.503 B01
- Issued
- Jun 29, 2016
- Abate by
- Aug 8, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(b)(1): The employer did not verify fall protection training by preparing a written certification record: a) On or about June 27, 2016, the employer did not prepare written certification records related to employee fall protection training. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Elite Exteriors, LLC.
View Elite Exteriors, LLC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341580678.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.