EDINBURG, TX —
OSHA Inspection: AAA ELECTRICAL SIGNS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of AAA ELECTRICAL SIGNS in 2205 UNIVERSITY DR, EDINBURG, TX 78540 (NAICS 339950). OSHA activity number 341589414.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AAA ELECTRICAL SIGNS
- Site address
- 2205 UNIVERSITY DR
- City
- EDINBURG
- State
- TX
- ZIP
- 78540
- Mailing
- P.O. BOX 3245, DONNA, TX 78537
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 339950
- Employees
- 3
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.180 D04 IV
- Issued
- Oct 13, 2016
- Abate by
- Nov 8, 2016
- Penalty
- Initial $5,487 · Current $3,292 Reduced
General-duty citation text
29 CFR 1910.180(d)(4)(iv): Worn, cracked, or distorted parts such as pins, bearings, shafts, gears, rollers and locking devices. On June 23, 2016, the employer provided a working platform with a locking pin mechanism that had been cracked/ damaged as to degrade the structural competence of the mechanism as it attaches to the truck crane. Employees were working from the bucket platform, providing maintenance to a business sign approximately 20 feet above ground.
Recent events (2)
- — I (S) $3292.2
- — Z (S) $5487
1910.333 A01
- Issued
- Oct 13, 2016
- Abate by
- Nov 8, 2016
- Penalty
- Initial $4,489 · Current $2,693 Reduced
General-duty citation text
29 CFR 1910.333(a)(1): Live parts to which an employee may be exposed shall be de-energized before the employee works on or near them, unless the employer can demonstrate that de-energizing introduces additional or increased hazards or is infeasible due to equipment design or operational limitations. Live parts that operate at less than 50 volts to ground need not be de-energized if there will be no increased exposure to electrical burns or to explosion due to electric arcs. On June 23, 2016, the employer did not establish safety-related work practices consisting of de-energizing live parts to prevent electrical shock and or other injury resulting from direct electrical contact when performing work on circuits which were or could be energized.
Recent events (2)
- — I (S) $2693.4
- — Z (S) $4489
1910.180 D03 III
- Issued
- Oct 13, 2016
- Abate by
- Nov 8, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.180(d)(3)(iii): Frequent Inspections were not conducted to identify whether safety devices were fully functioning. On June 23, 2016, and times prior thereto, the employer provided a crane hook with a locking lever that was damaged. Employees have potential for exposure to struck-by hazards as a result of an improperly secured load.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.180 D04 II
- Issued
- Oct 13, 2016
- Abate by
- Nov 8, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.180(d)(4)(ii): Loose bolts or rivets. On June 23, 2016, and times prior thereto, employees conducted crane operations utilizing improperly applied Crosby wire termination clips. The "U" bolt on the Crosby clip was missing a nut and was ineffective in securing the load. Employees have potential for exposure to struck-by hazards as a result of an improperly secured load.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at AAA Electrical Signs