Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SCICAST INTERNATIONAL, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SCICAST INTERNATIONAL, INC. in 650 ROUTE 100 NORTH, BECHTELSVILLE, PA 19505 (NAICS 331521). OSHA activity number 341596237.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Scicast International, INC. — free Get an email when a new federal OSHA severe-injury report for Scicast International, INC. is published. One employer, no account, unsubscribe in one click.
Site address
650 ROUTE 100 NORTH
City
BECHTELSVILLE
State
PA
ZIP
19505
Mailing
650 ROUTE 100 NORTH, BECHTELSVILLE, PA 19505
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331521
Employees
47
Ownership type
A

4 citations on file for this inspection.

1910.147 D05 II

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 19, 2016
Abate by
Nov 30, 2017
Penalty
Initial $7,483 · Current $3,200 Reduced
29 CFR 1910.147(d)(5)(ii): Where there was a possibility of re-accumulation of stored energy to a hazardous level, verification of isolation was not continued until the servicing or maintenance was completed, or until the possibility of such accumulation:    a) #3 Amp Die Casting - Employees changing the tip on the shot rod were exposed to stored energy from not ensuring the auto ladle retractor arm was not disabled, on or about April 19th, 2016.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (3)
  • — F (S) $3200
  • — C (S) $7483
  • — Z (S) $7483

1910.147 C07 I

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 19, 2016
Abate by
Nov 30, 2017
Penalty
Initial $7,483 · Current $3,200 Reduced
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that employees acquired the knowledge and skills required for the safe application, usage and removal of energy control devices:    a) #3 Amp Die Casting - Employees changing the shot rod tip were exposed to struck-by hazards from a lack of training on stored energy on the auto ladle retractor arm, on or about April 19th, 2016.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (3)
  • — F (S) $3200
  • — C (S) $7483
  • — Z (S) $7483

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 19, 2016
Abate by
Nov 30, 2017
Penalty
Initial $7,483 · Current $3,200 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    a) #3 Amp Die Casting - Employees changing the tip on the shot rod were exposed to a struck-by hazard from an auto ladle retractor arm behind an easily removed temporary, on or about April 19th, 2016.    No abatement certification or documentation required.
Recent events (3)
  • — F (S) $3200
  • — C (S) $7483
  • — Z (S) $7483

1910.305 A02 X

Other-than-serious 1 instance 2 exposed
Issued
Sep 19, 2016
Abate by
Nov 30, 2017
Penalty
Initial $3,742 · Current $875 Reduced
29 CFR 1910.305(a)(2)(x): 29 CFR 1910.305(a)(2)(x):  Flexible cords and cables were not protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points:    a) 7A Employee Cooling Fans - Employees using the cooling fans were exposed to electrical hazards from unprotected power cords with cuts in the cords, on or about June 29th, 2016.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (3)
  • — F (O) $875.36
  • — C (S) $3742
  • — Z (S) $3742

View Scicast International, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341596237.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.