BECHTELSVILLE, PA —
OSHA Inspection: SCICAST INTERNATIONAL, INC.
Follow-up inspection · Safety discipline
At a glance
On , OSHA opened a follow-up safety inspection of SCICAST INTERNATIONAL, INC. in 650 ROUTE 100 NORTH, BECHTELSVILLE, PA 19505 (NAICS 331521). OSHA activity number 341596419.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SCICAST INTERNATIONAL, INC.
- Site address
- 650 ROUTE 100 NORTH
- City
- BECHTELSVILLE
- State
- PA
- ZIP
- 19505
- Mailing
- 650 ROUTE 100 NORTH, BECHTELSVILLE, PA 19505
What kind of inspection was it?
- Inspection type
- Follow-up (F)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331521
- Employees
- 47
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.147 C04 I
- Issued
- Sep 23, 2016
- Penalty
- Initial $14,965 · Current $6,841 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Die Casting - Procedures were not developed, documented and utilized for the control of potentially hazardous energy on Die Casting #2 exposing employees to hazards when engaging in repair and maintenance activities, on or about May 26th, 2016. b) Die Casting - Procedures were not developed, documented and utilized for the control of potentially hazardous energy on Die Casting #5 exposing employees to hazards when engaging in repair and maintenance activities, on or about May 26th, 2016. c) Die Casting - Procedures were not developed, documented and utilized for the control of potentially hazardous energy on Die Casting #7 exposing employees to hazards when engaging in repair and maintenance activities, on or about May 26th, 2016. d) Die Casting - Procedures were not developed, documented and utilized for the control of potentially hazardous energy on Die Casting #8 exposing employees to hazards when engaging in repair and maintenance activities, on or about May 26th, 2016. e) Die Casting - Procedures were not developed, documented and utilized for the control of potentially hazardous energy on Die Casting #Z2 exposing employees to hazards when engaging in repair and maintenance activities, on or about May 26th, 2016. f) Die Casting - Procedures were not developed, documented and utilized for the control of potentially hazardous energy on Die Casting #3 - Amp exposing employees to hazards when engaging in repair and maintenance activities, on or about May 26th, 2016. g) Die Shop - Procedures were not developed, documented and utilized for the control of potentially hazardous energy on the Haus VF3 machine exposing employees to hazards when engaging in repair and maintenance activities, on or about May 26th, 2016. h) Die Shop - Procedures were not developed, documented and utilized for the control of potentially hazardous energy on the EDM machine exposing employees to hazards when engaging in repair and maintenance activities, on or about May 26th, 2016. i) Die Shop - Procedures were not developed, documented and utilized for the control of potentially hazardous energy on the Saw exposing employees to hazards when engaging in repair and maintenance activities, on or about May 26th, 2016. j) Sanding Room - Procedures were not developed, documented and utilized for the control of potentially hazardous energy on the Steel Blaster exposing employees to hazards when engaging in repair and maintenance activities, on or about May 26th, 2016. k) Sanding Room - Procedures were not developed, documented and utilized for the control of potentially hazardous energy on the table blaster exposing employees to hazards when engaging in repair and maintenance activities, on or about May 26th, 2016. l) Sanding Room - Procedures were not developed, documented and utilized for the control of potentially hazardous energy on the Barrel Blaster exposing employees to hazards when engaging in repair and maintenance activities, on or about May 26th, 2016. m) Sanding Room - Procedures were not developed, documented and utilized for the control of potentially hazardous energy on the Sand Blaster exposing employees to hazards when engaging in repair and maintenance activities, on or about May 26th, 2016. n) Sanding Room - Procedures were not developed, documented and utilized for the control of potentially hazardous energy on the Corn Cob exposing employees to hazards when engaging in repair and maintenance activities, on or about May 26th, 2016. o) Fab Department - Procedures were not developed, documented and utilized for the control of potentially hazardous energy on the US Surgical Drill exposing employees to hazards when engaging in repair and maintenance activities, on or about May 26th, 2016. p) Fab Department - Procedures were not developed, documented and utilized for the control of potentially hazardous energy on the Trim Die Press exposing employees to hazards when engaging in repair and maintenance activities, on or about May 26th, 2016. q) Shippin Department - Procedures were not developed, documented and utilized for the control of potentially hazardous energy on the Air Compressor exposing employees to hazards when engaging in repair and maintenance activities, on or about May 26th, 2016. r) Outside Shed - Procedures were not developed, documented and utilized for the control of potentially hazardous energy on the Air Compressor exposing employees to hazards when engaging in repair and maintenance activities, on or about May 26th, 2016. s) CNC Department - Procedures were not developed, documented and utilized for the control of potentially hazardous energy on Lathe #1 exposing employees to hazards when engaging in repair and maintenance activities, on or about May 26th, 2016. t) CNC Department - Procedures were not developed, documented and utilized for the control of potentially hazardous energy on Lathe #2 exposing employees to hazards when engaging in repair and maintenance activities, on or about May 26th, 2016. u) CNC Department - Procedures were not developed, documented and utilized for the control of potentially hazardous energy on Lathe #3 exposing employees to hazards when engaging in repair and maintenance activities, on or about May 26th, 2016. v) CNC Department - Procedures were not developed, documented and utilized for the control of potentially hazardous energy on My Center machine #2 exposing employees to hazards when engaging in repair and maintenance activities, on or about May 26th, 2016. w) CNC Department - Procedures were not developed, documented and utilized for the control of potentially hazardous energy on My Center machine #3 exposing employees to hazards when engaging in repair and maintenance activities, on or about May 26th, 2016. x) CNC Department - Procedures were not developed, documented and utilized for the control of potentially hazardous energy on My Center machine #4 exposing employees to hazards when engaging in repair and maintenance activities, on or about May 26th, 2016. y) CNC Department - Procedures were not developed, documented and utilized for the control of potentially hazardous energy on My Center machine #5 exposing employees to hazards when engaging in repair and maintenance activities, on or about May 26th, 2016. z) CNC Department - Procedures were not developed, documented and utilized for the control of potentially hazardous energy on My Center machine #6 exposing employees to hazards when engaging in repair and maintenance activities, on or about May 26th, 2016. aa) CNC Department - Procedures were not developed, documented and utilized for the control of potentially hazardous energy on My Center machine #7 exposing employees to hazards when engaging in repair and maintenance activities, on or about May 26th, 2016. bb) CNC Department - Procedures were not developed, documented and utilized for the control of potentially hazardous energy on the Haus VF#2 exposing employees to hazards when engaging in repair and maintenance activities, on or about May 26th, 2016. No abatement certification or documentation required. SciCast International, Inc was previously cited for a violation of this occupational safety and health standard 1910.147(c)(4)(i), which was contained in OSHA inspection number 1045904, citation number 1, item number 1, and was affirmed as a final order on 01/11/2016, with respect to a workplace located at 650 Route 100 North, Bechtelsville, PA 19505.
Recent events (3)
- — F (S) $6841
- — C (R) $14965
- — Z (R) $14965
More inspections at Scicast International, INC.