Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,473Inspections Most recent open 2026-07-28 Last loaded 2026-07-31

OSHA Inspection: VESTAS TOWERS AMERICA

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of VESTAS TOWERS AMERICA in 100 TOWERS DR, PUEBLO, CO 81004 (NAICS 221115). OSHA activity number 341652725.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Vestas Towers America — free Get an email when a new federal OSHA severe-injury report for Vestas Towers America is published. One employer, no account, unsubscribe in one click.
Site address
100 TOWERS DR
City
PUEBLO
State
CO
ZIP
81004
Mailing
100 TOWERS DR, PUEBLO, CO 81004
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
221115
Employees
721
Ownership type
A

2 citations on file for this inspection.

1910.253 B02 IV

Serious Gravity 1 1 instance 23 exposed
Issued
Aug 18, 2016
Abate by
Aug 26, 2016
Penalty
Initial $5,345 · Current $3,207 Reduced
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use:  (a)  On or about July 6, 2016, employees were exposed to fire and explosion hazards where compressed gas cylinders that were not in use were stored without caps.    Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $3207
  • — Z (S) $5345

1910.253 B04 III

Serious Gravity 1 1 instance 23 exposed
Issued
Aug 18, 2016
Abate by
Aug 26, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials, a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:  a)  On or about July 6, 2016, and at times prior, employees were exposed to fire and explosion hazards where oxygen cylinders were stored immediately adjacent to propylene and propane cylinders.  Abatement Note:  Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Vestas Towers America's full OSHA safety record →