SINKING SPRING, PA —
OSHA Inspection: BACHMAN'S ROOFING, BUILDING & REMODELING, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of BACHMAN'S ROOFING, BUILDING & REMODELING, INC. in 3000 REGENCY DRIVE, SINKING SPRING, PA 19608 (NAICS 238160). OSHA activity number 341693745.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BACHMAN'S ROOFING, BUILDING & REMODELING, INC.
- Site address
- 3000 REGENCY DRIVE
- City
- SINKING SPRING
- State
- PA
- ZIP
- 19608
- Mailing
- 36 SOUTH ELM STREET, WERNERSVILLE, PA 19565
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 85
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B10
- Issued
- Sep 22, 2016
- Penalty
- Initial $48,013 · Current $12,471 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system: (a) 3000 Regency Drive, Sinking Springs, PA - The employee was observed performing framing work activity on a 3 in 12 pitch residential porch roof without the benefit of a fall protection system, thereby exposing employees to a fall of approximately 9 feet 9 inches to the lower cement porch, and 10 feet 1 1/2 inches to the ground below, on or about August 11, 2016. No abatement certification or documentation required. Bachman's Roofing, Building & Remodeling, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard CFR 1926.501(b)(13), which was contained in OSHA inspection number 1112679, citation number 1, item number 1a and was affirmed as a final order on April 22, 2016, with respect to a workplace located at 100 Independence Court Blandon, PA. Bachman's Roofing, Building & Remodeling, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard CFR 1926.501(b)(13), which was contained in OSHA inspection number 1014285, citation number 1, item number 1a and was affirmed as a final order on February 24, 2015, with respect to a workplace located at 1222 Delaware Avenue Wyomissing, PA. Bachman's Roofing, Building & Remodeling, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard CFR 1926.501(b)(13), which was contained in OSHA inspection number 980871, citation number 1, item number 1 and was affirmed as a final order on July 17, 2014, with respect to a workplace located at 1680 East Thistle Drive Wyomissing, PA. Bachman's Roofing, Building & Remodeling, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard CFR 1926.501(b)(13), which was contained in OSHA inspection number 980261, citation number 1, item number 1 and was affirmed as a final order on July 17, 2014, with respect to a workplace located at 1513 Cromwell Street Wyomissing, PA. --------------------------------------------------------------------------------------------------------------------------------- Cit 01 Item 001 violation modified from Repeat to Serious; standard modified from 1926.501(b)(13) to 1926.501(b)(10); penalty modified from $48,013 to $12,471.
Recent events (2)
- — I (S) $12471
- — Z (R) $48013
1926.1060 B
- Issued
- Sep 22, 2016
- Penalty
- Initial $10,974 · Current $5,345 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: (a) 3000 Regency Drive, Sinking Springs, PA - Employees were observed using an aluminum extension ladder that did not extend at least 3 feet above the landing surface to the building, thereby exposing employees to a fall hazard of approximately 13 feet to the ground below, on or about August 11, 2016. No abatement certification or documentation required. Bachman's Roofing, Building & Remodeling, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard CFR 1926.1053(b)(1) which was contained in OSHA inspection number 980871, citation number 1, item number 3 and was affirmed as a final order on August 8, 2014, with respect to a workplace located at 1680 East Thistle Drive Wyomissing PA. -------------------------------------------------------------------------------------------------------------------------------------------- Cit 01 Item 002 violation modified from Repeat to Serious; standard modified from 1926.1053(b)(1) to 1926.1060(b); penalty modified from $10,974 to $5,345.
Recent events (2)
- — I (S) $5345
- — Z (R) $10974
More inspections at Bachman'S Roofing, Building & Remodeling, INC.
View Bachman'S Roofing, Building & Remodeling, INC.'s full OSHA safety record →