BELVIDERE, IL —
OSHA Inspection: CORRUGATED METALS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CORRUGATED METALS, INC. in 6550 REVLON DRIVE, BELVIDERE, IL 61008 (NAICS 332114). OSHA activity number 341707412.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CORRUGATED METALS, INC.
- Site address
- 6550 REVLON DRIVE
- City
- BELVIDERE
- State
- IL
- ZIP
- 61008
- Mailing
- 6550 REVLON DRIVE, BELVIDERE, IL 61008
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332114
- Employees
- 18
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.137 C02 XII
- Issued
- Nov 23, 2016
- Abate by
- Jan 3, 2017
- Penalty
- Initial $2,726 · Current $1,902 Reduced
General-duty citation text
29 CFR 1910.137(c)(2)(xii): The employer shall certify that equipment has been tested in accordance with the requirements of paragraphs (c)(2)(iv), (c)(2)(vii)(D), (c)(2)(viii), (c)(2)(ix), and (c)(2)(xi) of this section. The certification shall identify the equipment that passed the test and the date it was tested and shall be made available upon request to the Assistant Secretary for Occupational Safety and Health and to employees or their authorized representatives: On or about 03 August 2016, the employer did not ensure that the rubber insulating gloves issued for employee use had been tested within the past six months since being placed into service to ensure protection at the rated voltage. Certification was not made available to the Secretary's representative upon request. Employees were exposed to electric shock hazards when performing electrical work. Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $1902
- — Z (S) $2726
1910.335 A01 I
- Issued
- Nov 23, 2016
- Abate by
- Jan 3, 2017
- Penalty
- Initial $2,726 · Current $0 Reduced
General-duty citation text
29 CFR 1910.335(a)(1)(i): Employees working in areas where there are potential electrical hazards shall be provided with, and shall use, electrical protective equipment that is appropriate for the specific parts of the body to be protected and for the work to be performed. On or about 03 August 2016, and on prior dates, an employee gained access to a live electrical panel to reset fuses/breakers in a 480volt live electrical panel and did not wear appropriate electrical protective equipment, including but not limited to the following, to protect against electrical shock and Arc flash/blast injuries: a) Rubber insulating gloves with leather protectors. b) Arc-Rated clothing such as arc-rated long-sleeve shirt and pants, or arc-rated coverall. c) Hearing protection (canal inserts). d) Arc-Rated flash suit, hood or balaclava. Abatement documentation is required of this item in accordance with 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $0
- — Z (S) $2726
1910.335 A01 V
- Issued
- Nov 23, 2016
- Abate by
- Jan 3, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.335(a)(1)(v): Employees shall wear protective equipment for the eyes or face wherever there is danger of injury to the eyes or face from electric arcs or flashes or from flying objects resulting from electrical explosion. On or about 03 August 2016, and on prior dates, an employee who gained access to a live electrical panel to reset fuses/breakers in a 480volt live electrical panel, did not wear appropriate protective equipment, such as safety glasses and an arc-rated face shield, to protect the eyes and face against electrical arc flash/blast injuries. Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.332 B01
- Issued
- Nov 23, 2016
- Penalty
- Initial $2,726 · Current $2,374 Reduced
General-duty citation text
29 CFR 1910.332(b)(1): Practices addressed in this standard. Employees shall be trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertain to their respective job assignments. On or about 03 August 2016, and on dates prior, employees are required to enter 480volt electrical panel to check fuses and breakers for tripping and reset if needed. The employees were not trained in and familiar with safety-related work practices, such as the use of special precautionary techniques, personal protective equipment (PPE) and insulating and shielding materials. The employees were exposed to shock and arc flash hazards. Abatement documentation is not required for this item.
Recent events (2)
- — I (S) $2374
- — Z (S) $2726
1910.333 A
- Issued
- Nov 23, 2016
- Penalty
- Initial $2,726 · Current $0 Reduced
General-duty citation text
29 CFR 1910.333(a): Safety-related work practices shall be employed to prevent electric shock or other injuries resulting from either direct or indirect electrical contacts, when work is performed near or on equipment or circuits which are or may be energized. The specific safety-related work practices shall be consistent with the nature and extent of the associated electrical hazards. On or about 03 August 2016, and on prior dates, the employer did not ensure that appropriate work practices were employed while performing live electrical work at up to 480 volts. Employees were exposed to electrical shock and arc flash/blast injuries. Abatement documentation is not required of this item.
Recent events (2)
- — I (S) $0
- — Z (S) $2726
1910.333 B02 I
- Issued
- Nov 23, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.333(b)(2)(i): The employer shall maintain a written copy of the procedures outlined in paragraph (b)(2) and shall make it available for inspection by employees and by the Assistant Secretary of Labor and his or her authorized representatives. Note: The written procedures may be in the form of a copy of paragraph (b) of this section. On or about 03 August 2016, and on prior dates, the employer did not maintain procedures to ensure parts were de-energized, locked out and tagged in accordance with paragraph (b). This exposed employee(s) assigned to perform work on 480v circuits to electric shock, electrocution, and arc flash/blast. Abatement documentation is not required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.334 C01
- Issued
- Nov 23, 2016
- Abate by
- Jan 3, 2017
- Penalty
- Initial $2,726 · Current $2,726
General-duty citation text
29 CFR 1910.334(c)(1): Only qualified persons may perform testing work on electric circuits or equipment. On or about 03 August 2016, and on prior dates, unqualified employees were exposed to inadvertent contact with live electrical components when they were required to enter 480 volt electrical panels to reset fuses and circuit breakers. Employees were exposed to shock and arc flash hazards. Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $2726
- — Z (S) $2726
1910.333 C02
- Issued
- Nov 23, 2016
- Abate by
- Jan 3, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.333(c)(2): Only qualified persons may work on electric circuit parts or equipment that have not been deenergized under the procedures of paragraph (b) of this section. Such persons shall be capable of working safely on energized circuits and shall be familiar with the proper use of special precautionary techniques, personal protective equipment, insulating and shielding materials, and insulated tools. On or about 03 August 2016, and on prior dates, an employee gained access to a live electrical panel to reset fuses/breakers in a 480volt panel. The employee was not trained in and familiar with safety-related work practices such as the use of special precautionary techniques, personal protective equipment (PPE) and insulating and shielding materials. The employee was exposed to shock and arc flash hazards. Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.335 A01 IV
- Issued
- Nov 23, 2016
- Abate by
- Jan 3, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.335(a)(1)(iv): Employees shall wear nonconductive head protection wherever there is a danger of head injury from electric shock or burns due to contact with exposed energized parts. On or about 03 August 2016, and on prior dates, an employee who gained access to a live electrical panel to reset fuses/breakers in a 480volt live electrical panel, did not wear nonconductive head protection, such as a hard hat with dielectric properties. This exposed employees to shock and arc flash hazards. Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.334 C03
- Issued
- Nov 23, 2016
- Abate by
- Dec 30, 2016
- Penalty
- Initial $374 · Current $0 Reduced
General-duty citation text
29 CFR 1910.334(c)(3): Rating of equipment. Test instruments and equipment and their accessories shall be rated for the circuits and equipment to which they will be connected and shall be designed for the environment in which they will be used: On or about August 3, 2016, the employer provided multimeters and clamp-on ammeters for use that were not rated to safely test circuits operating at up to 480Volts AC. Abatement certification is required for this item in accordance with 29 CFR 1903.19(c).
Recent events (2)
- — I (O) $0
- — Z (O) $374
More inspections at Corrugated Metals, INC.
View Corrugated Metals, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332114)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341707412.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.