SAIPAN, MP —
OSHA Inspection: NORTH PAC CORPORATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NORTH PAC CORPORATION in BUILDING K NORTHERN MARIANAS COLLEGE, SAIPAN, MP 96950 (NAICS 236220). OSHA activity number 341721991.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NORTH PAC CORPORATION
- Site address
- BUILDING K NORTHERN MARIANAS COLLEGE
- City
- SAIPAN
- State
- MP
- ZIP
- 96950
- Mailing
- PO BOX 501031, SAIPAN, MP 96950
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 17
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.404 A02
- Issued
- Sep 30, 2016
- Abate by
- Oct 13, 2016
- Penalty
- Initial $2,850 · Current $2,850
General-duty citation text
29 CFR 1926.404(a)(2): A grounded conductor was attached to a terminal or lead so as to reverse designated polarity: a) On August 25, 2015, on the east side of Building K, a job made extension cord used to power a Dewalt battery charger and other power tools was wired in reverse polarity, exposing the employees to an electrical hazards.
Recent events (3)
- — F (S) $2850
- — C (S) $2850
- — Z (S) $2850
1926.404 B01 I
- Issued
- Sep 30, 2016
- Abate by
- Oct 13, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. a) On August 25, 2016, on the east side of Building K, the employer did not use either a ground fault circuit interrupter or an assured equipment grounding conductor program to protect employees from electrical hazards.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1926.451 F14
- Issued
- Sep 30, 2016
- Abate by
- Oct 13, 2016
- Penalty
- Initial $2,850 · Current $2,850
General-duty citation text
29 CFR 1926.451(f)(14): Makeshift devices, such as but not limited to boxes and barrels, were used on top of scaffold platforms to increase the working level height of employees: a) On August 25, 2015, on the east side of Building K, a job-made bench was used on top of the scaffolding for painting the eaves of the roof on a job-made bench, exposing the employees to a fall hazard.
Recent events (3)
- — F (S) $2850
- — C (S) $2850
- — Z (S) $2850
1926.403 B02
- Issued
- Sep 30, 2016
- Abate by
- Oct 11, 2016
- Penalty
- Initial $5,701 · Current $3,951 Reduced
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: a) On August 25 2016, on the east side of Building, a metal electrical box designed to be mounted in a wall was used on an extension cord to provide power tools used on the construction site. The North Pac Corporation was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.403(b)(2), which was contained in OSHA inspection number 930163, citation number 1, item number 6 and was affirmed as a final order on December 10, 2013, with respect to a workplace located at the Army Reserve Center Parking Lot in Saipan, MP.
Recent events (3)
- — F (R) $3950.73
- — C (R) $5701
- — Z (R) $5701
1926.405 B01
- Issued
- Sep 30, 2016
- Abate by
- Oct 12, 2016
- Penalty
- Initial $5,701 · Current $3,950 Reduced
General-duty citation text
29 CFR 1926.405(b)(1): Unused openings in cabinets, boxes, and fittings were not also effectively closed: a) On August 25, 2016, on the east side of Building K, a metal gang box lying on the ground connected to an black extension cord had unused openings, exposing employees to electrical hazards. The North Pac Corporation was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.405(b)(1), which was contained in OSHA inspection number 930163, citation number 1, item number 7 and was affirmed as a final order on December 10, 2013, with respect to a workplace located at the Army Reserve Center Parking Lot in Saipan, MP.
Recent events (3)
- — F (R) $3950
- — C (R) $5701
- — Z (R) $5701
More inspections at North PAC Corporation
View North PAC Corporation's full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in MP
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341721991.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.