ASHTABULA, OH —
OSHA Inspection: ITEN INDUSTRIES, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ITEN INDUSTRIES, INC. in 4602 BENEFIT AVE., ASHTABULA, OH 44004 (NAICS 326199). OSHA activity number 341775773.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ITEN INDUSTRIES, INC.
- Site address
- 4602 BENEFIT AVE.
- City
- ASHTABULA
- State
- OH
- ZIP
- 44004
- Mailing
- 4602 BENEFIT AVE., ASHTABULA, OH 44004
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 175
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.147 C04 II B
- Issued
- Nov 23, 2016
- Penalty
- Initial $11,224 · Current $6,734 Reduced
8870
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: On or about September 7, 2016, the employer failed to ensure all sources of energy on the A45 Punch Press were identified including how to isolate them.
Recent events (2)
- — I (S) $6734.4
- — Z (S) $11224
1910.147 C06 I
- Issued
- Nov 23, 2016
- Penalty
- Initial $0 · Current $0
8870
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: On or about September 7, 2016, the employer failed to perform an annual audit of the A45 Punch Press Lockout/Tagout Procedures.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 D
- Issued
- Nov 23, 2016
- Penalty
- Initial $0 · Current $0
8870
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): On or about August 31 2016, employees were exposed to machine hazards associated with electrical, and thermal as sources of energy. The employer failed to implement energy control application steps as the A 45 Punch Press, Heater B was not shut down or turned off to perform the servicing work. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)] and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.332 B01
- Issued
- Nov 23, 2016
- Abate by
- Dec 20, 2016
- Penalty
- Initial $11,224 · Current $6,734 Reduced
8870
General-duty citation text
29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments: On or about September 7, 2016, the employer failed to train employees in safety-related work practices prior to allowing them to work/test live electrical up to and including 480VAC.
Recent events (2)
- — I (S) $6734.4
- — Z (S) $11224
1910.335 A02 I
- Issued
- Nov 23, 2016
- Abate by
- Dec 14, 2016
- Penalty
- Initial $11,224 · Current $6,734 Reduced
8870
General-duty citation text
29 CFR 1910.335(a)(2)(i): When working near exposed energized conductors or circuit parts, each employee did not use insulated tools or handling equipment when the tools or handling equipment might have made contact with such conductors or parts: On or about August 31, 2016, the employer failed to ensure employees performing preventative maintenance were provided voltage rated tooling while working near live electrical, up to and including 480VAC.
Recent events (2)
- — I (S) $6734.4
- — Z (S) $11224
More inspections at Iten Industries, INC.
View Iten Industries, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 326199)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341775773.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.