Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GREEN EARTH ENERGY PHOTOVOLTAIC CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of GREEN EARTH ENERGY PHOTOVOLTAIC CORPORATION in 280 N. MAIN ST, EAST LONGMEADOW, MA 01028 (NAICS 221114). OSHA activity number 341822062.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Green Earth Energy Photovoltaic Corporation — free Get an email when a new federal OSHA severe-injury report for Green Earth Energy Photovoltaic Corporation is published. One employer, no account, unsubscribe in one click.
Site address
280 N. MAIN ST
City
EAST LONGMEADOW
State
MA
ZIP
01028
Mailing
208 SHAKER RD, LONGMEADOW, MA 01106
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
221114
Employees
60
Ownership type
A

3 citations on file for this inspection.

1926.502 D15

Other-than-serious 1 instance 1 exposed
Issued
Nov 14, 2016
Abate by
Nov 18, 2016
Penalty
Initial $6,236 · Current $1,000 Reduced
29 CFR 1926.502(d)(15): Anchorages used for attachment of personal fall arrest equipment were not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached:    a)280 N. Main St., East Longmeadow, MA: On or about October 3, 2016, an employee was installing part of a solar panel system on the roof of this building more than 13 feet above the ground below, and his snaphook was engaged to his horizontal lifeline  which was wrapped around a gas line on the roof, which was secured to the roof via a C clamp to a block of wood, which is not intended to support any imposed load.
Recent events (3)
  • — F (O) $1000
  • — C (S) $6236
  • — Z (S) $6236

1926.502 D16 III

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Nov 14, 2016
Penalty
Initial $6,236 · Current $0 Reduced
29 CFR 1926.502(d)(16)(iii): Fall protection equipment was not  rigged such that an employee can neither free fall more than 6 feet (1.8 m), nor contact any lower level:  a)280 N. Main St., East Longmeadow, MA: On or about October 3, 2016, an employee was installing part of a solar panel system on the roof of this building more than 13 feet above the ground below, and his fall protection ropes were rigged so that if he fell, he would contact the ground he was working above as the fall was 13 feet, and he had more than 20 feet of lifeline to deploy before his fall was arrested.
Recent events (3)
  • — F (S) $0
  • — C (S) $6236
  • — Z (S) $6236

1926.503 B01

Other-than-serious 1 instance 1 exposed
Issued
Nov 14, 2016
Abate by
Nov 25, 2016
Penalty
Initial $700 · Current $0 Reduced
29 CFR 1926.503(b)(1): The employer had not prepared a written certification record for all employees that have been provided fall protection training:    a)280 N. Main St., East Longmeadow, MA: On or about October 3, 2016, the employer had not prepared a written certification that for all employees that had been provided fall  protection training.
Recent events (3)
  • — F (O) $0
  • — C (O) $700
  • — Z (O) $700

View Green Earth Energy Photovoltaic Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341822062.