STRATFORD, CT —
OSHA Inspection: GREEN EARTH ENERGY PHOTOVOLTAIC CORPORATION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of GREEN EARTH ENERGY PHOTOVOLTAIC CORPORATION in 497 SECOND HILL LANE, STRATFORD, CT 06614 (NAICS 238160). OSHA activity number 343271417.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GREEN EARTH ENERGY PHOTOVOLTAIC CORPORATION
- Site address
- 497 SECOND HILL LANE
- City
- STRATFORD
- State
- CT
- ZIP
- 06614
- Mailing
- 2 NORTH ROAD BUILDING 3, EAST WINDSOR, CT 06088
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 75
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.178 L01 I
- Issued
- Jul 23, 2018
- Penalty
- Initial $5,691 · Current $1,140 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l). Worksite: The employer did not ensure through providing training and performing evaluation that the employee required to operate the JCB all-terrain forklift (PIT) was competent to operate the PIT safely at all times.
Recent events (3)
- — F (S) $1140
- — C (S) $5691
- — Z (S) $5691
1926.501 B04 I
- Issued
- Jul 23, 2018
- Abate by
- Aug 16, 2018
- Penalty
- Initial $9,959 · Current $2,000 Reduced
General-duty citation text
29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights), more than six feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes. Worksite: The employer did not ensure that the employees required to perform roofing work on the roof of a commercial building were protected from falling through unguarded skylights by the use of appropriate protective systems/devices. On or about 06/08/2018, one of employees performing roofing work on the above roof fell approximately 12 feet 5 inches to lower level through one of unguarded skylights and sustained minor injuries from the incident.
Recent events (3)
- — F (S) $2000
- — C (S) $9959
- — Z (S) $9959
1926.503 A01
- Issued
- Jul 23, 2018
- Abate by
- Aug 16, 2018
- Penalty
- Initial $7,114 · Current $1,400 Reduced
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards. Worksite: The employer did not ensure that the employees exposed to fall hazards while performing roofing work of the commercial building were trained in fall hazards and the procedures to be followed to minimize such hazards.
Recent events (3)
- — F (S) $1400
- — C (S) $7114
- — Z (S) $7114
1926.501 B10
- Issued
- Jul 23, 2018
- Abate by
- Aug 16, 2018
- Penalty
- Initial $49,796 · Current $15,460 Reduced
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system. Worksite: The employer did not ensure that the employees working on the low sloped roof at a height above 6 feet were protected from falling by guardrails, safety nets, personal fall arrest systems or a monitoring system. Green Earth Energy Photovoltaic Corporation was previously cited for a violation of an equivalent Occupational Safety and Health standard 29 CFR 1926.501(b)(1) which was contained in OSHA Inspection Number 1106885, Citation Number 2, Item Number 1, issued on 12/11/2015 with respect to a workplace located at 27 Lawnacre Road, Windsor Locks, CT and became a final order on 12/22/2015.
Recent events (3)
- — F (R) $15460
- — C (R) $49796
- — Z (R) $49796
More inspections at Green Earth Energy Photovoltaic Corporation
View Green Earth Energy Photovoltaic Corporation's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in CT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343271417.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.