Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: COEXTRUDED PLASTIC TECHNOLOGIES, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of COEXTRUDED PLASTIC TECHNOLOGIES, INC. in 3706 ENTERPRISE DRIVE, JANESVILLE, WI 53546 (NAICS 326112). OSHA activity number 341838449.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Coextruded Plastic Technologies, INC. — free Get an email when a new federal OSHA severe-injury report for Coextruded Plastic Technologies, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3706 ENTERPRISE DRIVE
City
JANESVILLE
State
WI
ZIP
53546
Mailing
3706 ENTERPRISE DRIVE, JANESVILLE, WI 53546
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326112
Employees
39
Ownership type
A

3 citations on file for this inspection.

1910.23 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 17, 2017
Abate by
Mar 6, 2017
Penalty
Initial $4,310 · Current $3,017 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:  On or about October 13, 2016, employee(s) who worked on the portable platform used for lubrication and maintenance tasks on line QB1 were exposed to fall hazards due guardrails that lacked sufficient top rail height and a midrail.
Recent events (2)
  • — I (S) $3017
  • — Z (S) $4310

1910.110 F02 I

Serious Gravity 5 1 instance 3 exposed
Issued
Feb 17, 2017
Abate by
Mar 6, 2017
Penalty
Initial $5,387 · Current $3,771 Reduced
29 CFR 1910.110(f)(2)(i): Containers in storage were not located so as to minimize exposure to excessive temperature rise, physical damage, or tampering by unauthorized persons:  Between the dates of October 13, 2016 and January 31, 2017, 100 pound containers of liquid propane (LP) used to power hand torches on line QB2 were not located so as to prevent exposure to physical damage posed by forklift traffic.
Recent events (2)
  • — I (S) $3770.9
  • — Z (S) $5387

1910.335 A01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 17, 2017
Abate by
Mar 20, 2017
Penalty
Initial $5,387 · Current $3,771 Reduced
29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not provided with electrical protective equipment that was appropriate for the specific parts of the body that needed to be protected and for the work being performed:  On October 13, 2016 and on dates prior, employee(s) whose job tasks involved electrical testing and troubleshooting on live electrical circuits up to 480 volts were not provided with electrical protective equipment.
Recent events (2)
  • — I (S) $3770.9
  • — Z (S) $5387

View Coextruded Plastic Technologies, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341838449.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.