PHILADELPHIA, PA —
OSHA Inspection: CONSTRUCT DESIGN CORP, INC.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of CONSTRUCT DESIGN CORP, INC. in 208 S 13TH ST, PHILADELPHIA, PA 19107 (NAICS 236220). OSHA activity number 341913408.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CONSTRUCT DESIGN CORP, INC.
- Site address
- 208 S 13TH ST
- City
- PHILADELPHIA
- State
- PA
- ZIP
- 19107
- Mailing
- 1910 SPRING GARDEN ST, PHILADELPHIA, PA 19130
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 5
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.100 A
- Issued
- May 10, 2017
- Abate by
- May 16, 2017
- Penalty
- Initial $3,259 · Current $3,259
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets. a) Jobsite: Roof - Employees handling suspended roof enclosure panels, weighing up to approximately 800 lbs., were exposed to impact injuries without the protection of protective helmets. Observed on or about 11/15/16.
Recent events (1)
- — Z (S) $3259
1926.501 B01
- Issued
- May 10, 2017
- Abate by
- May 16, 2017
- Penalty
- Initial $3,803 · Current $3,803
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge 6 feet or more above a lower level was not protected from falling by the use of a guardrail system, safety net system, or personal fall arrest system. a) Jobsite: Roof - Employees installing retractable roof enclosure panels along open and unprotected roof edges, approximately 40 feet above ground level, were exposed to fall hazards without the use of a fall protection system. Observed on or about 11/15/16.
Recent events (1)
- — Z (S) $3803
1926.1053 B01
- Issued
- May 10, 2017
- Abate by
- May 16, 2017
- Penalty
- Initial $2,716 · Current $2,716
General-duty citation text
29 CFR 1926.1053(b)(1): The side rails of portable ladders used for access did not extend at least 3 feet above the upper landing surface, or was secured at its top to a rigid support that will not deflect and along with a grasping devise to assist employees mounting and dismounting the ladder. a) Jobsite: 3rd floor, roof - The portable ladder used to access the roof did not extend 3 feet above the upper landing surface to assist the employees performing a retractable roof enclosure installation in mounting and dismounting the ladder. Noted on or about 11/15/16.
Recent events (1)
- — Z (S) $2716
1926.1425 A
- Issued
- May 10, 2017
- Abate by
- May 16, 2017
- Penalty
- Initial $3,803 · Current $3,803
General-duty citation text
29 CFR 1926.1425(a): Where available, hoisting routes that minimize the exposure of employees to hoisted loads were not used, to the extent consistent with public safety. a) Jobsite: Roof - Employees receiving suspended retractable roof enclosure panels, weighing up to approximately 800 lbs., were exposed to struck by and falling object hazards without the use of a hoisting route to minimize the exposure. Observed on or about 11/15/16.
Recent events (1)
- — Z (S) $3803
1926.1428 A
- Issued
- May 10, 2017
- Abate by
- May 30, 2017
- Penalty
- Initial $2,716 · Current $2,716
General-duty citation text
29 CFR 1926.1428(a): The employer of the signal person did not ensure that each signal person met the Qualifications Requirements (paragraph (c) of this section) prior to giving any signals. a) Jobsite: Roof - The employer exposed employees receiving retractable roof enclosure panels to hazards associated with hoisting operations by permitting an employee to perform signal person activities without ensuring the employee met the Qualification Requirements prior to giving any signals. Noted on or about 11/15/16.
Recent events (1)
- — Z (S) $2716
More inspections at Construct Design Corp, INC.
View Construct Design Corp, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341913408.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.