PHILADELPHIA, PA —
OSHA Inspection: CONSTRUCT DESIGN CORP, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of CONSTRUCT DESIGN CORP, INC. in 208 S 13TH STREET, PHILADELPHIA, PA 19107 (NAICS 238160). OSHA activity number 342526738.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CONSTRUCT DESIGN CORP, INC.
- Site address
- 208 S 13TH STREET
- City
- PHILADELPHIA
- State
- PA
- ZIP
- 19107
- Mailing
- 1910 SPRING GARDEN ST, PHILADELPHIA, PA 19130
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 3
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.501 B01
- Issued
- Nov 6, 2017
- Abate by
- Nov 13, 2017
- Penalty
- Initial $3,803 · Current $3,803
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge 6 feet or more above a lower level was not protected from falling by the use of a guardrail system, safety net system, or personal fall arrest system. (a) 208 S 13th St - On or about 5/31/17, Employees were not provided with fall protection when installing parapet lighting on open and unprotected roof edges, exposing employees to falls of approximately 40 feet.
Recent events (1)
- — Z (S) $3803
1926.501 B04 I
- Issued
- Nov 6, 2017
- Abate by
- Nov 13, 2017
- Penalty
- Initial $3,803 · Current $3,803
General-duty citation text
29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes. (a) 208 S 13th St - On or about 5/31/17, Employees were not provided with a fall protection system when performing work next to a retractable skylight, exposing employees to falls of approximately 14 feet.
Recent events (1)
- — Z (S) $3803
1926.1053 B01
- Issued
- Nov 6, 2017
- Abate by
- Nov 13, 2017
- Penalty
- Initial $3,803 · Current $3,803
General-duty citation text
29 CFR 1926.1053(b)(1): The side rails of portable ladders used for access did not extend at least 3 feet above the upper landing surface, or was secured at its top to a rigid support that will not deflect and along with a grasping devise to assist employees mounting and dismounting the ladder. a) 208 S 13th St - On or about 5/31/17, A portable stepladder used to access the roof did not extend 3 feet above the upper landing surface to assist the employees performing work on the roof in mounting and dismounting the ladder, exposing employees to fall hazards.
Recent events (1)
- — Z (S) $3803
1926.1053 B04
- Issued
- Nov 6, 2017
- Abate by
- Nov 13, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a) 208 S 13th St - On or about 5/31/17, a 12-foot portable stepladder was used in the closed position by employees to access the roof, exposing employees to fall hazards.
Recent events (1)
- — Z (S) $0
1926.1053 B13
- Issued
- Nov 6, 2017
- Abate by
- Nov 13, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a) 208 S 13th St - On or about 5/31/17, the top step and top cap of a portable stepladder was used by employees to access the roof, exposing employees to fall hazards.
Recent events (1)
- — Z (S) $0
1926.1053 B16
- Issued
- Nov 6, 2017
- Abate by
- Nov 13, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired. a) 208 S 13th St - On or about 5/31/17, A portable stepladder with a broken rung was not withdrawn from service, exposing employees to fall hazards.
Recent events (1)
- — Z (S) $0
More inspections at Construct Design Corp, INC.
View Construct Design Corp, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342526738.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.