Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DARKOTECH, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DARKOTECH, INC. in 2011 KRUG STREET, ALBANY, GA 31705 (NAICS 321920). OSHA activity number 341922540.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Darkotech, INC. — free Get an email when a new federal OSHA severe-injury report for Darkotech, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
DARKOTECH, INC.
Site address
2011 KRUG STREET
City
ALBANY
State
GA
ZIP
31705
Mailing
281 INDUSTRIAL PARK BOULEVARD, DAWSON, GA 39842
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321920
Employees
17
Ownership type
A

8 citations on file for this inspection.

1910.23 C01

Serious Gravity 1 1 instance 2 exposed
Issued
Mar 22, 2017
Abate by
May 15, 2017
Penalty
Initial $3,802 · Current $2,376 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards. Note: Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard.    a). At the workplace - On or about and times prior to November 16, 2016, there were two loading docks that were not equipped standard railing, thus exposing employees to a fall hazard.
Recent events (2)
  • — I (S) $2376
  • — Z (S) $3802

1910.132 A

Other-than-serious 1 instance 11 exposed
Issued
Mar 22, 2017
Abate by
Apr 17, 2017
Penalty
Initial $3,802 · Current $0 Reduced
29 CFR 1910.132(a): Protective equipment was not provided when necessary whenever hazards capable of causing injury and impairment were encountered.    a). At the workplace - On or about and times prior to November 17, 2016, personal protective equipment was not provided to protect employees arms when wood pallets with unknown substances were dismantled by woodworking machinery, thus exposing employees to skin irritants.
Recent events (2)
  • — I (O) $0
  • — Z (S) $3802

1910.141 B01 I

Serious Gravity 5 2 instances 14 exposed
Issued
Mar 22, 2017
Abate by
Apr 17, 2017
Penalty
Initial $7,605 · Current $0 Reduced
29 CFR 1910.141(b)(1)(i): Potable water was not provided in all places of employment, for drinking, washing of the person, cooking, washing of foods, washing of cooking or eating utensils, washing of food preparation or processing premises, and personal service rooms.    a). At the workplace - On or about and times prior to November 16, 2016, an adequate supply of potable water was not provided for employee consumption, thus exposing employees to health hazards.     b). At the workplace - On or about and times prior to November 16, 2016, potable water was not provided for employees to wash their person, thus exposing employees to health hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7605

1910.147 C01

Serious Gravity 5 1 instance 4 exposed
Issued
Mar 22, 2017
Abate by
May 15, 2017
Penalty
Initial $6,338 · Current $4,912 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative.    a). At the workplace - On or about and times prior to November 16, 2016, the employer did not have an established energy control program for employees conducting maintenance tasks such as, but not limited to saw blade replacement on woodworking machinery (e.g. bandsaws), thus exposing employees to an amputation injury.
Recent events (2)
  • — I (S) $4912
  • — Z (S) $6338

1910.178 P01

Other-than-serious 1 instance 2 exposed
Issued
Mar 22, 2017
Abate by
Apr 17, 2017
Penalty
Initial $3,802 · Current $2,376 Reduced
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been  taken out of service until restored to safe operating condition(s):    a). At the workplace - On or about and times prior to November 16, 2016, a Tusk lift truck (model: 300 PGH-20) was operated with a damaged left rear tire, thus exposing employees to a tip-over hazard.
Recent events (2)
  • — I (O) $2376
  • — Z (S) $3802

1910.213 B01

Serious Gravity 10 2 instances 4 exposed
Issued
Mar 22, 2017
Abate by
May 15, 2017
Penalty
Initial $8,873 · Current $7,447 Reduced
29 CFR 1910.213(b)(1): Woodworking machine(s) were not provided with mechanical or electrical power controls so located that the operator could cut off the power from the machine without leaving his position at the point of operation.    a). Front of the workplace building - On or about and times prior to November 16, 2016, the Hawk (model: D-Hawk3ph) horizontal bandsaw did not have power control(s) located in a position in which both operators could turn of the bandsaw without leaving their position, thus exposing employees to amputation injuries.    b). Rear of the workplace building - On or about and times prior to November 16, 2016, the horizontal bandsaw did not have power control(s) located in a position in which both operators could turn off the power from the bandsaw without leaving their position, thus exposing employees to amputation injuries.
Recent events (2)
  • — I (S) $7447
  • — Z (S) $8873

1910.303 F02

Other-than-serious 1 instance 2 exposed
Issued
Mar 22, 2017
Abate by
Apr 17, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident.    a). Front of the workplace building - On or about and times prior to November 17, 2016, the circuit breaker box had several individual circuit breakers that were not marked with their intended purpose, thus exposing employees to a programmatic hazard.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G02 II

Other-than-serious 1 instance 2 exposed
Issued
Mar 22, 2017
Abate by
Apr 17, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(2)(ii): In locations where electric equipment was likely to be exposed to physical damage, enclosures or guards were not so arranged and of such strength as to prevent such damage.    a). At the workplace - On or about and times prior to November 16, 2016, the internal electrical wiring on the control box that operated the Hawk bandsaw was not fully guarded to protect the wiring from physical damage, thus exposing employees to electrical hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Darkotech, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341922540.