ALBANY, GA —
OSHA Inspection: DARKOTECH, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DARKOTECH, INC. in 2011 KRUG STREET, ALBANY, GA 31705 (NAICS 321920). OSHA activity number 341922540.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DARKOTECH, INC.
- Site address
- 2011 KRUG STREET
- City
- ALBANY
- State
- GA
- ZIP
- 31705
- Mailing
- 281 INDUSTRIAL PARK BOULEVARD, DAWSON, GA 39842
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321920
- Employees
- 17
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.23 C01
- Issued
- Mar 22, 2017
- Abate by
- May 15, 2017
- Penalty
- Initial $3,802 · Current $2,376 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards. Note: Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard. a). At the workplace - On or about and times prior to November 16, 2016, there were two loading docks that were not equipped standard railing, thus exposing employees to a fall hazard.
Recent events (2)
- — I (S) $2376
- — Z (S) $3802
1910.132 A
- Issued
- Mar 22, 2017
- Abate by
- Apr 17, 2017
- Penalty
- Initial $3,802 · Current $0 Reduced
General-duty citation text
29 CFR 1910.132(a): Protective equipment was not provided when necessary whenever hazards capable of causing injury and impairment were encountered. a). At the workplace - On or about and times prior to November 17, 2016, personal protective equipment was not provided to protect employees arms when wood pallets with unknown substances were dismantled by woodworking machinery, thus exposing employees to skin irritants.
Recent events (2)
- — I (O) $0
- — Z (S) $3802
1910.141 B01 I
- Issued
- Mar 22, 2017
- Abate by
- Apr 17, 2017
- Penalty
- Initial $7,605 · Current $0 Reduced
General-duty citation text
29 CFR 1910.141(b)(1)(i): Potable water was not provided in all places of employment, for drinking, washing of the person, cooking, washing of foods, washing of cooking or eating utensils, washing of food preparation or processing premises, and personal service rooms. a). At the workplace - On or about and times prior to November 16, 2016, an adequate supply of potable water was not provided for employee consumption, thus exposing employees to health hazards. b). At the workplace - On or about and times prior to November 16, 2016, potable water was not provided for employees to wash their person, thus exposing employees to health hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $7605
1910.147 C01
- Issued
- Mar 22, 2017
- Abate by
- May 15, 2017
- Penalty
- Initial $6,338 · Current $4,912 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative. a). At the workplace - On or about and times prior to November 16, 2016, the employer did not have an established energy control program for employees conducting maintenance tasks such as, but not limited to saw blade replacement on woodworking machinery (e.g. bandsaws), thus exposing employees to an amputation injury.
Recent events (2)
- — I (S) $4912
- — Z (S) $6338
1910.178 P01
- Issued
- Mar 22, 2017
- Abate by
- Apr 17, 2017
- Penalty
- Initial $3,802 · Current $2,376 Reduced
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s): a). At the workplace - On or about and times prior to November 16, 2016, a Tusk lift truck (model: 300 PGH-20) was operated with a damaged left rear tire, thus exposing employees to a tip-over hazard.
Recent events (2)
- — I (O) $2376
- — Z (S) $3802
1910.213 B01
- Issued
- Mar 22, 2017
- Abate by
- May 15, 2017
- Penalty
- Initial $8,873 · Current $7,447 Reduced
General-duty citation text
29 CFR 1910.213(b)(1): Woodworking machine(s) were not provided with mechanical or electrical power controls so located that the operator could cut off the power from the machine without leaving his position at the point of operation. a). Front of the workplace building - On or about and times prior to November 16, 2016, the Hawk (model: D-Hawk3ph) horizontal bandsaw did not have power control(s) located in a position in which both operators could turn of the bandsaw without leaving their position, thus exposing employees to amputation injuries. b). Rear of the workplace building - On or about and times prior to November 16, 2016, the horizontal bandsaw did not have power control(s) located in a position in which both operators could turn off the power from the bandsaw without leaving their position, thus exposing employees to amputation injuries.
Recent events (2)
- — I (S) $7447
- — Z (S) $8873
1910.303 F02
- Issued
- Mar 22, 2017
- Abate by
- Apr 17, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident. a). Front of the workplace building - On or about and times prior to November 17, 2016, the circuit breaker box had several individual circuit breakers that were not marked with their intended purpose, thus exposing employees to a programmatic hazard.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 G02 II
- Issued
- Mar 22, 2017
- Abate by
- Apr 17, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(2)(ii): In locations where electric equipment was likely to be exposed to physical damage, enclosures or guards were not so arranged and of such strength as to prevent such damage. a). At the workplace - On or about and times prior to November 16, 2016, the internal electrical wiring on the control box that operated the Hawk bandsaw was not fully guarded to protect the wiring from physical damage, thus exposing employees to electrical hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Darkotech, INC.
View Darkotech, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 321920)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341922540.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.