Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GILSTER-MARY LEE CORPORATION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of GILSTER-MARY LEE CORPORATION in 10 INDUSTRIAL PARK, STEELEVILLE, IL 62288 (NAICS 311823). OSHA activity number 341922862.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Gilster-Mary LEE Corporation — free Get an email when a new federal OSHA severe-injury report for Gilster-Mary LEE Corporation is published. One employer, no account, unsubscribe in one click.
Site address
10 INDUSTRIAL PARK
City
STEELEVILLE
State
IL
ZIP
62288
Mailing
10 INDUSTRIAL PARK, STEELEVILLE, IL 62288
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311823
Employees
360
Ownership type
A

2 citations on file for this inspection.

1910.147 D

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 1, 2017
Abate by
Feb 28, 2017
Penalty
Initial $9,961 · Current $6,475 Reduced
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):    Employees conducting machine servicing, such as adjusting the speed of the conveyor system on Line #15, were exposed to amputation hazards and energy isolating devices were not physically located and operated in such a manner as to isolate the machine or equipment from the energy sources, and lock out or tag out devices were not affixed to each energy isolating device.  The employer did not require that employees follow the sequence outlined in 29 CFR 1910.147.
Recent events (2)
  • — I (S) $6475
  • — Z (S) $9961

1910.219 M02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 1, 2017
Abate by
Feb 28, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.219(m)(2)(i): Expanded metal, sheet or perforated metal, and wire mesh was not securely fastened to frame.  On Line #15, the north side metal guard covering the belt and gear drives was not secured to the frame or otherwise configured to prevent the removal of the guard while the drives were operating.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Gilster-Mary LEE Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341922862.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.