Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TRIPLE J SAIPAN, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of TRIPLE J SAIPAN, INC. in INTERSECTION OF SAN ISIDRO AND BEACH RD., SAIPAN, MP 96950 (NAICS 236220). OSHA activity number 341957330.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Triple J Saipan, INC. — free Get an email when a new federal OSHA severe-injury report for Triple J Saipan, INC. is published. One employer, no account, unsubscribe in one click.
Site address
INTERSECTION OF SAN ISIDRO AND BEACH RD.
City
SAIPAN
State
MP
ZIP
96950
Mailing
P.O. BOX 500487 GARAPAN, SAIPAN, MP 96950
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
915
Ownership type
A

3 citations on file for this inspection.

1926.501 B04 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 18, 2017
Penalty
Initial $5,541 · Current $5,541
29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes.   a) On December 7, 2016, two employees were working on top of a two-story concrete block building standing on exposed rebar, jackhammering the concrete roof and were not protected from falling to the lower level.
Recent events (1)
  • — Z (S) $5541

1926.701 B

Serious Gravity 1 1 instance 30 exposed
Issued
Jan 18, 2017
Penalty
Initial $4,155 · Current $4,155
29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall or come against, was not guarded to eliminate the hazard of impalement:   a) On December 7, 2016, approximately 3/8 inch diameter rebar protruded about 24 to 30 inches from the ground from an excavation area where employees were working above exposing employees to an impalement hazard.
Recent events (1)
  • — Z (S) $4155

1926.404 B01 I

Other-than-serious 1 instance 30 exposed
Issued
Jan 18, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites.   a) On December 7, 2016, at the temporary power source area, ground fault circuit interrupters or an assured equipment grounding conductor program was not used, exposing employees to electrical hazards.
Recent events (1)
  • — Z (O) $0

View Triple J Saipan, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341957330.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.