Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NN, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of NN, INC. in 1 CATAMORE BOULEVARD, EAST PROVIDENCE, RI 02914 (NAICS 326199). OSHA activity number 341962603.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch NN, INC. — free Get an email when a new federal OSHA severe-injury report for NN, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
NN, INC.
Site address
1 CATAMORE BOULEVARD
City
EAST PROVIDENCE
State
RI
ZIP
02914
Mailing
1 CATAMORE BOULEVARD, EAST PROVIDENCE, RI 02914
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
73
Ownership type
A

3 citations on file for this inspection.

1910.212 A03 II

Serious Gravity 10 1 instance 5 exposed
Issued
Dec 14, 2016
Abate by
Feb 1, 2017
Penalty
Initial $8,730 · Current $4,365 Reduced
29 CFR 1910.212(a)(3)(ii): Points of operation of machinery were not guarded to prevent employees from having any part of their body in the danger zones during operating cycles:     (a) Tool Room:  On or about 12/9/2016, employees were exposed to point of operation hazards while operating unguarded Bridgeport milling machines.
Recent events (2)
  • — I (S) $4365
  • — Z (S) $8730

1910.147 C04 II

Other-than-serious 1 instance 6 exposed
Issued
Dec 14, 2016
Abate by
Feb 1, 2017
Penalty
Initial $700 · Current $0 Reduced
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D):     (a) Worksite:  On or about 12/9/2016, the employer had not yet developed and documented machine specific Lockout/Tag-out procedures for the equipment at the worksite.
Recent events (2)
  • — I (O) $0
  • — Z (O) $700

1910.147 C07 I B

Other-than-serious 1 instance 8 exposed
Issued
Dec 14, 2016
Abate by
Feb 1, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i)(B): Affected employees were not instructed in the purpose and use of the energy control procedure:   (a) Worksite:  On or about 12/9/2016, the employer had not trained affected employees on the purpose and function of Lockout/Tag-out.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View NN, INC.'s full OSHA safety record →