Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NN, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of NN, INC. in 821 WEST ALGONQUIN ROAD, ALGONQUIN, IL 60102 (NAICS 333514). OSHA activity number 347317828.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch NN, INC. — free Get an email when a new federal OSHA severe-injury report for NN, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
NN, INC.
Site address
821 WEST ALGONQUIN ROAD
City
ALGONQUIN
State
IL
ZIP
60102
Mailing
821 WEST ALGONQUIN ROAD, ALGONQUIN, IL 60102
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333514
Employees
52
Ownership type
A

3 citations on file for this inspection.

1910.147 C06 I

Other-than-serious Gravity 10 1 instance 2 exposed
Issued
Jul 12, 2024
Abate by
Nov 1, 2024
Penalty
Initial $16,131 · Current $7,000 Reduced
29 CFR  1910.147(c)(6)(i):The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.  a) On or about February 27, 2024, the employer did not conduct periodic inspections of the company's energy control procedures to ensure that the requirements of the lockout/tagout standard were met. The employer's hazardous energy control program had deficiencies, such as, but not limited to employees not locking out machines or equipment prior to servicing and maintenance activities on the Minster Power Press (SN: P2-100-29887).   Employees were exposed to crushing and amputation hazards while performing servicing and maintenance activities   Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (O) $7000
  • — Z (S) $16131

1910.147 C07 I A

Other-than-serious Gravity 10 1 instance 2 exposed
Issued
Jul 12, 2024
Penalty
Initial $16,131 · Current $0 Reduced
29 CFR  1910.147(c)(7)(i)(A):Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.  a) On or about February 27, 2024, the employer did not ensure that employees engaged in maintenance activities on the Minster Power Press (SN: P2-100-29887), received training in the recognition of applicable hazardous energy sources and the methods and means necessary for isolation and control. Employees were exposed to laceration, crushing and amputation hazards.  Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (O) $0
  • — Z (S) $16131

1910.147 D

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 12, 2024
Abate by
Nov 1, 2024
Penalty
Initial $16,131 · Current $9,200 Reduced
29 CFR  1910.147(d):Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence:  a)  On or about February 27, 2024, the employer did not ensure that employees implemented energy control steps prior to performing maintenance activities such as troubleshooting or die changes on the Minster Power Press (SN: P2-100-29887).  Hazardous energy (electrical and pneumatic) was not isolated exposing employees to crushing and amputation hazards in case of accidental start-up.   As a result, the remaining applicable energy control elements, involving machine isolation [1910.147(d)(3)], lockout/tagout device application [1910.147(d)(4)], dissipation of residual energy [1910.147(d)(5)(i)], and verification of isolation [1910.147(d)(6)] were not implemented to protect employees from machine hazards.  Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $9200
  • — Z (S) $16131

View NN, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347317828.