Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: A&M HOMES, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of A&M HOMES, LLC in DAVIS ST, FAIRMONT, WV 26554 (NAICS 236115). OSHA activity number 341964922.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch A&M Homes, LLC — free Get an email when a new federal OSHA severe-injury report for A&M Homes, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
A&M HOMES, LLC
Site address
DAVIS ST
City
FAIRMONT
State
WV
ZIP
26554
Mailing
1399 WINONA AVE, MORGANTOWN, WV 26505
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
4
Ownership type
A

5 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 19, 2017
Abate by
Jan 31, 2017
Penalty
Initial $2,173 · Current $1,304 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees that were exposed while working on or underneath improperly braced trusses:    a) Davis St. Fairmont: On or about December 8, 2016, employees were installing trusses on a new residential home.  The trusses erected, were not installed in accordance with BCSI "Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses" in that bracing for the top and bottom lateral bracing and the diagonal bracing was not installed.
Recent events (2)
  • — I (S) $1303.8
  • — Z (S) $2173

1926.34 A

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 19, 2017
Abate by
Jan 31, 2017
Penalty
Initial $2,173 · Current $1,304 Reduced
29 CFR 1926.34(a): Building or structure exits were not so arranged and maintained as to provide free and unobstructed egress from all parts of the building or structure at all times when it was occupied:    a) Back of house: On or about December 7, 2016 and times prior,  employees were required to climb over top or underneath a guard rail to enter or exit a residential home under construction.
Recent events (2)
  • — I (S) $1303.8
  • — Z (S) $2173

1926.501 B13

Serious Gravity 5 2 instances 2 exposed
Issued
Jan 19, 2017
Abate by
Jan 25, 2017
Penalty
Initial $2,173 · Current $1,304 Reduced
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m)  or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502:     a) Roof Structure: On or about December 8, 2016, an employee was on the trusses of a newly installed residential home, approximately 19 feet eave to eave to ground, guiding in and installing additional trusses without the use of fall protection.     b) 2nd Floor on Front of home: On or about December 8, 2016, employees  were exposed to a fall of 11 feet while working in front 3 window openings on a two story residence.  The window openings were not protected with a guardrail systems and the employees were not utilizing fall protection.
Recent events (2)
  • — I (S) $1303.8
  • — Z (S) $2173

1926.651 L

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 19, 2017
Abate by
Jan 25, 2017
Penalty
Initial $3,259 · Current $1,955 Reduced
29 CFR 1926.651(l): Walkways were not provided where employees or equipment were required or permitted to cross over excavations:    a)Back of home:  On or about December 8, 2016 and times prior, employees used a ladder laid across an excavation to gain access to the second floor of a new two story residential home.  The employer did not provide a walkway complete with guard rails to travel across the excavation.
Recent events (2)
  • — I (S) $1955.4
  • — Z (S) $3259

1926.1053 B04

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 19, 2017
Abate by
Jan 25, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed:  a) Back of the home: On or about December 8, 2016 and times prior, employees used a 6 foot Werner step ladder in the closed position, laid across a trench to access the second floor of a new residential home.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View A&M Homes, LLC's full OSHA safety record →