NORCROSS, GA —
OSHA Inspection: COLOR IMAGING, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of COLOR IMAGING, INC. in 4350 PEACHTREE INDUSTRIAL BLVD #100, NORCROSS, GA 30071 (NAICS 325992). OSHA activity number 341965028.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COLOR IMAGING, INC.
- Site address
- 4350 PEACHTREE INDUSTRIAL BLVD #100
- City
- NORCROSS
- State
- GA
- ZIP
- 30071
- Mailing
- 4350 PEACHTREE INDUSTRIAL BLVD #100, NORCROSS, GA 30071
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325992
- Employees
- 40
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.147 C04 II
- Issued
- Feb 21, 2017
- Abate by
- Mar 27, 2017
- Penalty
- Initial $8,873 · Current $4,880 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): On or about 12/8/2016 in the production, maintenance, warehouse, and packing areas at 4350 Peachtree Industrial Blvd, Ste 100 Norcross, GA: Where employees performed maintenance and or service on equipment such as the mixers, raw material process machines, water pumps, grinder, henschels, and fillers equipment, did not have clear and specific energy control procedures. The employer failed to address all of the energy sources in the procedures such as but not limited to electrical, pneumatic, and mechanical, water, gravity, and heat energy sources.
Recent events (2)
- — I (S) $4880.15
- — Z (S) $8873
1910.147 C06 I
- Issued
- Feb 21, 2017
- Abate by
- Mar 27, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: On or about 12/8/2016 in the production and maintenance areas at 4350 Peachtree Industrial Blvd, Ste 100 Norcross, GA: Where employees were repairing and servicing malfunctioning equipment, troubleshooting, setting up, clearing, unjamming, and adjusting equipment no periodic inspection was performed annually on the energy control procedures for the following equipment; a. Raw Material Mixing Equipment two (2) each, b. Raw Material Processing Equipment & Pumps two (2) each, c. Raw Material Grinder Equipment one (1) each, d. Grinded Material Henschels Additive Equipment one (1) each, and e. Finished Toner Filler Equipment three (3) each.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C07 I
- Issued
- Feb 21, 2017
- Abate by
- Mar 27, 2017
- Penalty
- Initial $5,387 · Current $2,963 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: On or about 12/8/2016 in the production and maintenance areas at 4350 Peachtree Industrial Blvd, Ste 100 Norcross, GA: Employees required to perform maintenance and servicing activities such as but not limited to; clearing, repairing, troubleshooting, unjamming, and setting up were not provided training on the specific energy control procedures for isolating and verifying the energy sources on the following equipment; a. Raw Material Mixing Equipment two (2) each, b. Raw Material Processing Equipment & Pumps two (2) each, c. Raw Material Grinder Equipment one (1) each, d. Grinded Material Henschels Additive Equipment one (1) each, and e. Finished Toner Filler Equipment three (3) each.
Recent events (2)
- — I (S) $2962.85
- — Z (S) $5387
1910.178 L01 I
- Issued
- Feb 21, 2017
- Abate by
- Mar 10, 2017
- Penalty
- Initial $3,232 · Current $1,778 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator was competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): On or about 12/8/2016 in the production and maintenance areas at 4350 Peachtree Industrial Blvd, Ste 100 Norcross, GA: Employees were allowed to operate powered industrial trucks at the site without having received formal instruction, including operator evaluation to determine the retention of the information.
Recent events (2)
- — I (S) $1777.6
- — Z (S) $3232
1910.178 L01 II
- Issued
- Feb 21, 2017
- Abate by
- Mar 10, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(1)(ii): The employer did not ensure that each operator had successfully completed the training required by paragraph (l), except as permitted by paragraph (l)(5), prior to permitting an employee to operate a On or about 12/8/2016 in the production and maintenance areas at 4350 Peachtree Industrial Blvd, Ste 100 Norcross, GA: Prior to allowing employees to operate powered industrial trucks to lift, load, unload, move material, drums, and other products, the employer failed to ensure they successfully completed training and evaluation.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Color Imaging, INC.
View Color Imaging, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 325992)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341965028.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.