Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DESIGN PRECAST & PIPE, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of DESIGN PRECAST & PIPE, INC. in 6639 HIGHWAY 93, ARNAUDVILLE, LA 70512 (NAICS 327390). OSHA activity number 342073251.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Design Precast & Pipe, INC. — free Get an email when a new federal OSHA severe-injury report for Design Precast & Pipe, INC. is published. One employer, no account, unsubscribe in one click.
Site address
6639 HIGHWAY 93
City
ARNAUDVILLE
State
LA
ZIP
70512
Mailing
15215 DEDEAUX RD., GULFPORT, MS 39503
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327390
Employees
15
Ownership type
A

7 citations on file for this inspection.

1910.110 F02 I

Serious Gravity 5 3 instances 12 exposed
Issued
May 24, 2017
Abate by
Jun 14, 2017
Penalty
Initial $6,519 · Current $3,911 Reduced
29 CFR 1910.110(f)(2)(i): Containers in storage were not located so as to minimize exposure to excessive temperature rise, physical damage, or tampering by unauthorized persons.  On or about January 24, 2017, at the Design Precast plant, Arnaudville, Louisiana; the employer did not ensure that containers consisting of hazardous materials were properly stored at the site. 50-gallon drums of petroleum liquids were kept outside and exposed to excessive heat/temperatures.
Recent events (2)
  • — I (S) $3911.4
  • — Z (S) $6519

1910.146 C01

Serious Gravity 1 1 instance 6 exposed
Issued
May 24, 2017
Abate by
Jun 9, 2017
Penalty
Initial $2,173 · Current $1,304 Reduced
29 CFR 1910.146(c)(1): The employer did not evaluate the workplace to determine if any spaces are permit-required confined spaces:  On or about January 24, 2017 at the Design Precast plant in Arnaudville, LA; the employer failed to evaluate the workplace to identify and classify every confined space as either a Permit-Required Confined Space or a Non-Permit Confined Space.  The employer allows employees to enter confined spaces to perform cleaning operations.
Recent events (2)
  • — I (S) $1303.8
  • — Z (S) $2173

1910.151 C

Serious Gravity 5 1 instance 12 exposed
Issued
May 24, 2017
Abate by
Jun 9, 2017
Penalty
Initial $6,519 · Current $3,911 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:  On or about January 24, 2017, at the Design Precast and Pipe facility, Arnaudville, Louisiana; the employer did not provide eye wash stations for the employees to use. The employees are exposed to chemicals that include but are not limited to: Alumina Oxide, Iron Oxide, Silica Oxide, Calcium Oxide, Calcium and Magnesium Sulfates and other corrosives.
Recent events (2)
  • — I (S) $3911.4
  • — Z (S) $6519

1910.252 A02 II

Serious Gravity 5 2 instances 4 exposed
Issued
May 24, 2017
Abate by
Jun 9, 2017
Penalty
Initial $6,519 · Current $3,911 Reduced
29 CFR 1910.252(a)(2)(ii): Suitable extinguishing equipment was not maintained in a state of readiness for instant use:  On or about January 24, 2017, at the Design Precast plant in Arnaudville, LA; the employer did not provide fire extinguishers for instant and ready use during welding operations.
Recent events (2)
  • — I (S) $3911.4
  • — Z (S) $6519

1910.253 B04 III

Serious Gravity 1 3 instances 12 exposed
Issued
May 24, 2017
Abate by
Jun 9, 2017
Penalty
Initial $2,173 · Current $1,304 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet:  On or about January 24, 2017, at the Design Precast & Pipe, Arnaudville, Louisiana; the employer allowed compressed gas cylinders containing oxygen and compressed gas cylinders containing acetylene to be stored together.  The cylinders were not separated by a fire barrier or distance of at least 20 feet.
Recent events (2)
  • — I (S) $1303.8
  • — Z (S) $2173

1910.1200 E01

Serious Gravity 1 1 instance 15 exposed
Issued
May 24, 2017
Abate by
Jun 9, 2017
Penalty
Initial $2,173 · Current $1,304 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  On or about January 24, 2017, at the Design Precast plant in Arnaudville, LA the employer did not maintain a site specific, written hazardous communication program.  Employees work with and around hazardous chemicals at the site, such as but not limited to, Alumina Oxide, Iron Oxide, Silica Oxide, Calcium Oxide, Calcium and Magnesium Sulfates, Oleic Acid, and diesel fuels.
Recent events (2)
  • — I (S) $1303.8
  • — Z (S) $2173

1903.2 A01

Other-than-serious 2 instances 15 exposed
Issued
May 24, 2017
Abate by
May 31, 2017
Penalty
Initial $900 · Current $540 Reduced
29 CFR 1903.2(a)(1): The employer did not post and keep posted OSHA notices informing employees of the protections and obligations provided for in the Act, and that for assistance and information, including copies of the Act and of specific safety and health standards, employees should contact the employer or the nearest office of the Department of Labor.      On or about January 24, 2017, at the Design Precast plant in Arnaudville, LA; the employer did not post Occupational Health & safety information, postings (OSHA Poster) in conspicuous places for the employees to read or have access to in the language that they are most comfortable reading.
Recent events (2)
  • — I (O) $540
  • — Z (O) $900

View Design Precast & Pipe, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342073251.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.