NORTH AURORA, IL —
OSHA Inspection: PENTAIR FLOW TECHNOLOGIES, LLC*
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of PENTAIR FLOW TECHNOLOGIES, LLC* in 800 AIRPORT RD., NORTH AURORA, IL 60542 (NAICS 333911). OSHA activity number 342083177.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PENTAIR FLOW TECHNOLOGIES, LLC*
- Site address
- 800 AIRPORT RD.
- City
- NORTH AURORA
- State
- IL
- ZIP
- 60542
- Mailing
- 800 AIRPORT RD., NORTH AURORA, IL 60542
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333911
- Employees
- 199
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.147 C06 I
- Issued
- Jul 10, 2017
- Abate by
- Aug 16, 2017
- Penalty
- Initial $9,054 · Current $9,054
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: On or about May 11, 2017, the employer did not conduct periodic inspections of the energy control procedures for the following equipment at least annually: a. Mori Seiki # 732 Horizontal Mill b. Okuma # 738 Horizontal Mill c. Toyota # 734 Horizontal Mill Employees were exposed to amputation and laceration hazards. Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (3)
- — F (S) $9054
- — C (S) $9054
- — Z (S) $9054
1910.147 D
- Issued
- Jul 10, 2017
- Abate by
- Aug 16, 2017
- Penalty
- Initial $12,675 · Current $12,675
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): On or about January 27, 2017 employees in the Custom Machine Shop performed servicing and maintenance tasks when performing setups on the following Horizontal Milling Machines: a. The Mori Seiki #732 b. The Okuma #738 c. The Toyota #734 Employees were not required to control hazardous energy sources in the following sequence: 1. Turn off and shut down the machines. 2. Physically locate and operate energy isolating devices in such a manner as to isolate the machines or equipment from the energy source(s). 3. Affix lockout or tagout devices to each energy isolating device. 4. Verify that isolation and de-energization of the machines or equipment have been accomplished. Employees were exposed to amputation and laceration hazards from the unexpected start up and/or the release of hazardous energy. Alternative protection, such a machine guarding, was not adequate. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1904.19(d).
Recent events (3)
- — F (S) $12675
- — C (S) $12675
- — Z (S) $12675
1910.212 A03 II
- Issued
- Jul 10, 2017
- Abate by
- Aug 16, 2017
- Penalty
- Initial $12,675 · Current $0 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): On or about January 27, 2017, the points of operation on the following machines were not guarded to prevent employees from having any part of their body in the danger zone during the operating cycle: a. The Mori Seiki #732 Horizontal Mill; b. The Okuma #738 Horizontal Mill; c. The Toyota # 734 Horizontal Mill; the employees were exposed to amputation and laceration hazards. Documentation is required of this item in accordance with 29 CFR 1903(d).
Recent events (3)
- — F (S) $0
- — C (S) $12675
- — Z (S) $12675
1910.332 B01
- Issued
- Jul 10, 2017
- Abate by
- Aug 16, 2017
- Penalty
- Initial $9,054 · Current $8,271 Reduced
General-duty citation text
29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments: On or about May 10, 2017, maintenance employees performed voltage testing on energized components (up to 480 volts) while troubleshooting machinery and equipment. Employees were not trained in and familiar with safety-related work practices, including the use of special precautionary techniques, personal protective equipment (PPE) and insulating and shielding materials. Employees were exposed to electrocution and arc flash/blast hazards. Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (3)
- — F (S) $8271
- — C (S) $9054
- — Z (S) $9054
1910.334 C01
- Issued
- Jul 10, 2017
- Abate by
- Aug 16, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(c)(1): Unqualified persons performed testing work on electric circuits or equipment. On or about May 10, 2017, unqualified employees performed voltage testing on energized components (up to 480 volts) while troubleshooting machinery and equipment. Employees were exposed to electrical shock and arc flash/blast hazards. Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.335 A01 I
- Issued
- Jul 10, 2017
- Abate by
- Aug 16, 2017
- Penalty
- Initial $9,054 · Current $0 Reduced
General-duty citation text
29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not using electrical protective equipment that was appropriate for the specific parts of the body to be protected and for the work to be performed: On or about May 10, 2017, maintenance employees who performed voltage testing on energized electrical components (480 volts) did not wear electrical protective equipment appropriate for the level of exposure, to protect against electrical shock and arc flash/blast injuries, including: 1. Hand protection: Rubber insulating gloves with leather protectors or arc-rated gloves; 2. Apparel: Arc-rated clothing such as arc-rated long-sleeve shirt and pants or arc-rated coverall, and leather footwear; 3. Head and face protection: Arc-rated face shield, arc-rated hard hat, arc-rated flash suit hood and/or balaclava; 4. Hearing protection: Hearing protectors (canal inserts). Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (3)
- — F (S) $0
- — C (S) $9054
- — Z (S) $9054
More inspections at Pentair Flow Technologies, LLC*
View Pentair Flow Technologies, LLC*'s full OSHA safety record →
More inspections in this industry (NAICS 333911)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342083177.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.