Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PENTAIR FLOW TECHNOLOGIES, LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of PENTAIR FLOW TECHNOLOGIES, LLC in 750 E. 9TH STREET, ASHLAND, OH 44805 (NAICS 331511). OSHA activity number 344512132.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pentair Flow Technologies, LLC — free Get an email when a new federal OSHA severe-injury report for Pentair Flow Technologies, LLC is published. One employer, no account, unsubscribe in one click.
Site address
750 E. 9TH STREET
City
ASHLAND
State
OH
ZIP
44805
Mailing
1101 MYERS PARKWAY, ASHLAND, OH 44805
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331511
Employees
320
Ownership type
A

3 citations on file for this inspection.

1910.1053 C

Deleted Serious Gravity 5 2 instances 2 exposed
Issued
May 13, 2020
Abate by
Jun 15, 2020
Penalty
Initial $9,639 · Current $0 Reduced

Hazardous substances 9000

29 CFR 1910.1053(c): The employer did not ensure that no employee was exposed to an airborne concentration of respirable crystalline silica in excess of 50 ug/m3, calculated as an 8-hour TWA.   a)     Pentair Flow Technologies, LLC is located at 1101 Myers Parkway, Ashland, OH; On or about February 13, 2020, at the production facility, an employee working in the knockout (Mash Room) production area was exposed to crystalline silica levels of 145.86 micrograms/ cubic meter which exceeds the permissible exposure limit PEL of 50 ug/m3. The sampling was performed for 417 minutes, and zero exposure was assumed for unsampled time.   b)     Pentair Flow Technologies, LLC located at 1101 Myers Parkway, Ashland, OH; On or about February 13, 2020, at the production facility, an employee working in the knockout (Mash Room) production area was exposed to crystalline silica levels of 139.01 micrograms/ cubic meter which exceeds the permissible exposure limit PEL of 50 ug/m3. The sampling was performed for 428 minutes, and zero exposure was assumed for unsampled time.
Recent events (3)
  • — F (S) $0
  • — C (S) $9639
  • — Z (S) $9639

1910.1053 F01

Serious Gravity 5 1 instance 6 exposed
Issued
May 13, 2020
Abate by
May 3, 2021
Penalty
Initial $0 · Current $4,820

Hazardous substances 9010

29 CFR 1910.1053(f)(1): The employer did not use engineering and work practice controls to reduce and maintain employee exposure to respirable crystalline silica to or below the PEL, unless the employer can demonstrate that such controls are not feasible.   a)     Pentair Flow Technologies, LLC is located at 1101 Myers Parkway, Ashland, OH. On or about February 13, 2020, at the production facility, employees working in the knock-out (Mash Room) production area were over-exposed to respirable crystalline silica after several engineering and/or work practice controls used by the employer were not effective to adequately reduce silica exposures below the PEL. Employees were wearing the appropriate tight fitting respirators while conducting their daily tasks.   Multi-step abatement     Step 1:  Effective respiratory protection shall be provided and used by exposed employees as an interim protective measure until feasible engineering and/or administrative controls can be implemented, or whenever such controls fail to reduce employee exposure to within permissible exposure limits.    Step 2:  Submit to the Area Director a written, detailed plan of abatement outlining a schedule for the implementation of engineering and/or administrative measures to control employee exposure to hazardous substances as referenced in this citation.  This plan shall include, at a minimum, target dates for the following actions which must be consistent with the abatement dates required by this citation:    1.     Evaluation of engineering/administrative control options; 2.     Selection of optimum control methods and completion of design; 3.     Procurement, installation and operation of selected control measures; 4.     Testing and acceptance or modification/redesign of controls.    Step 3:  Abatement shall have been completed by the implementation of feasible engineering controls and/or administrative controls upon verification of their effectiveness in achieving compliance.    Feasible engineering controls include, but are not limited to: 1.     Provide local ventilation to limit exposure to hazardous or toxic agents and environments within acceptable limits; the system shall be inspected periodically. 2.     Portable engineering control devices shall be used at the location to collect the air borne respirable crystalline silica, i.e., local HEPA filtered ventilation systems.     Date by which Step 1 must be abated:   /   /     Date by which Step 2 must be abated:   /   /    Date by which Step 3 must be abated:   /   /
Recent events (3)
  • — F (S) $4820
  • — C (S) $0
  • — Z (S) $0

1910.134 D01 III

Serious Gravity 10 1 instance 3 exposed
Issued
May 13, 2020
Abate by
May 3, 2021
Penalty
Initial $0 · Current $0
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form:    a)     Pentair Flow Technologies, LLC is located at 1101 Myers Parkway, Ashland, OH; On or about February 13, 2020, at the production facility; The employer did not ensure that respiratory hazards in the workplace were evaluated. This violation occurred on or about February 13, 2020 when the employer failed to evaluate the respiratory hazards in the cast molding area where the employees were potentially overexposed to silica during sand molding Hunter 10-1 and Hunter 10-2 machines operations.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

View Pentair Flow Technologies, LLC's full OSHA safety record →