FULTON, NY —
OSHA Inspection: UNIVERSAL METAL WORKS, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of UNIVERSAL METAL WORKS, LLC in 159 HUBBARD STREET, FULTON, NY 13069 (NAICS 332312). OSHA activity number 342156098.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- UNIVERSAL METAL WORKS, LLC
- Site address
- 159 HUBBARD STREET
- City
- FULTON
- State
- NY
- ZIP
- 13069
- Mailing
- 159 HUBBARD STREET, FULTON, NY 13069
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 25
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.147 C04 I
- Issued
- Mar 22, 2017
- Abate by
- Apr 26, 2017
- Penalty
- Initial $2,463 · Current $1,478 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) At the establishment, on or about 3/8/17: Where employees perform servicing, maintenance, set ups on various machinery or equipment, including, but not limited to press brakes, shears, laser cutter, mills, etc., the employer had not established specific energy control procedures to prevent the unexpected energizing, start up or release of stored energy of the equipment. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $1477.8
- — Z (S) $2463
1910.147 C07 I
- Issued
- Mar 22, 2017
- Abate by
- Apr 26, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: a) At the establishment, on or about 3/8/17: Affected employees were not provided training on the lockout/tagout program to ensure that the purpose and function of the energy control program was understood by employees and not all authorized employees were provided training to ensure that the knowledge and skills required for the safe application, usage and removal of energy controls were acquired by employees. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.215 A02
- Issued
- Mar 22, 2017
- Abate by
- Apr 3, 2017
- Penalty
- Initial $1,847 · Current $1,108 Reduced
General-duty citation text
29 CFR 1910.215(a)(2): Abrasive wheel(s) used on grinding machinery were not provided with safety guard(s) which covered the spindle end, nut, flange projections: a) Machining Area, on or about 3/8/17: A Palmgren bench grinder/polisher was not provided with a safety guard on the spindle end and nut projection for the right polishing wheel. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $1108.2
- — Z (S) $1847
1910.215 A04
- Issued
- Mar 22, 2017
- Abate by
- Apr 3, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(a)(4): Grinding machinery was not used with work rest(s) to support offhand grinding work: a) Machining Area, on or about 3/8/17: A Palmgren bench grinder/polisher was not provided with a work rest for the left grinding wheel. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.215 B09
- Issued
- Mar 22, 2017
- Abate by
- Apr 3, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): Guard for abrasive wheel machine where the operator stands in front of the machine was not constructed so that the peripheral protecting member could be adjusted to the constantly decreasing diameter of the wheel: a) Machining Area, on or about 3/8/17: A Palmgren bench grinder/polisher was not provided with a tongue guard for the left grinding wheel. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.252 B02 III
- Issued
- Mar 22, 2017
- Abate by
- Apr 3, 2017
- Penalty
- Initial $1,847 · Current $1,108 Reduced
General-duty citation text
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields: a) Welding Area, on or about 3/8/17: Two welding stations adjacent to the main aisle were not provided with welding curtains. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $1108.2
- — Z (S) $1847
1910.37 A04
- Issued
- Mar 22, 2017
- Abate by
- Apr 3, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times: a) North end of shop, on or about 3/8/17: Emergency lighting over the exit door was not working. Abatement certification must be submitted for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.178 L04 III
- Issued
- Mar 22, 2017
- Abate by
- Apr 11, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: a) At the establishment, on or about 3/8/17: An evaluation of each powered industrial truck operator's performance was not conducted at least once every three years in that the last evaluations conducted were 2/5/13. Abatement certification must be submitted for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Universal Metal Works, LLC
View Universal Metal Works, LLC's full OSHA safety record →
More inspections in this industry (NAICS 332312)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342156098.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.