Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: GENERAL PLASTIC EXTRUSIONS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of GENERAL PLASTIC EXTRUSIONS, INC. in 1238 KASSON DRIVE, PRESCOTT, WI 54021 (NAICS 322223). OSHA activity number 342178936.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch General Plastic Extrusions, INC. for free Get an email when a new federal OSHA severe-injury report for General Plastic Extrusions, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1238 KASSON DRIVE
City
PRESCOTT
State
WI
ZIP
54021
Mailing
1238 KASSON DRIVE, PRESCOTT, WI 54021
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
322223
Employees
62
Ownership type
Private (A)

3 citations on file for this inspection.

1910.212 A01

Serious Gravity 10 1 instance 10 exposed
Issued
Jul 31, 2017
Abate by
Jan 8, 2018
Penalty
Initial $8,873 · Current $4,437 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    (a) Main production area; On or about March 8, 2017 an employee was injured while manually attaching the plastic web to a rotating core on a winder machine that did not have adequate guarding.
Recent events (2)
  • · I (S) $4437
  • · Z (S) $8873

1910.303 B01

Serious Gravity 5 1 instance 62 exposed
Issued
Jul 31, 2017
Penalty
Initial $5,070 · Current $2,535 Reduced
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees:    (a) Production area; An electrical outlet adjacent to the exit in the main production area was damaged.
Recent events (2)
  • · I (S) $2535
  • · Z (S) $5070

1910.37 A03

Other-than-serious 1 instance 62 exposed
Issued
Jul 31, 2017
Penalty
Initial $711 · Current $356 Reduced
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:    (a) Production area; An exit route in the production area was obstructed by a portable winder.
Recent events (2)
  • · I (O) $356
  • · Z (O) $711

View General Plastic Extrusions, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342178936.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.