Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MID CONTINENT STEEL AND WIRE INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of MID CONTINENT STEEL AND WIRE INC. in 2700 CENTRAL AVENUE, POPLAR BLUFF, MO 63901 (NAICS 332618). OSHA activity number 342209186.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch MID Continent Steel and Wire INC. — free Get an email when a new federal OSHA severe-injury report for MID Continent Steel and Wire INC. is published. One employer, no account, unsubscribe in one click.
Site address
2700 CENTRAL AVENUE
City
POPLAR BLUFF
State
MO
ZIP
63901
Mailing
2700 CENTRAL AVENUE, POPLAR BLUFF, MO 63901
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332618
Employees
400
Ownership type
A

5 citations on file for this inspection.

1910.147 C05 I

Serious Gravity 10 80 instances 100 exposed
Issued
Apr 20, 2017
Abate by
Jun 7, 2017
Penalty
Initial $12,675 · Current $12,000 Reduced
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing or blocking of machines or equipment from energy sources:    At 2700 Central Avenue, Poplar Bluff, MO, specifically inside of the Plastic Strip Department, employees were exposed to caught-in hazards on machines such as, but not limited to, an Injection Molded Plastic Collator, m/n PS160 and employees were not provided with suitable lockout/tagout devices (hardware) for isolating, securing, or blocking of machines or equipment from energy sources. This violation was observed on 03/31/17.
Recent events (2)
  • — I (S) $12000
  • — Z (S) $12675

1910.147 D03

Serious Gravity 10 80 instances 100 exposed
Issued
Apr 20, 2017
Abate by
Jun 7, 2017
Penalty
Initial $12,675 · Current $0 Reduced
29 CFR 1910.147(d)(3):  All energy isolating devices that are needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s):    At 2700 Central Avenue, Poplar Bluff, MO, specifically inside of the Plastic Strip Department, employees were exposed to caught-in hazards on machines such as, but not limited to, an Injection Molded Plastic Collator, m/n PS160, and did not isolate all energy sources prior to clearing jams.  This violation was observed on 03/31/17.
Recent events (2)
  • — I (S) $0
  • — Z (S) $12675

1910.147 C07 I A

Deleted Serious Gravity 10 80 instances 100 exposed
Issued
Apr 20, 2017
Abate by
Jun 7, 2017
Penalty
Initial $12,675 · Current $0 Reduced
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control:  At 2700 Central Avenue, Poplar Bluff, MO, specifically inside of the Plastic Strip Department, employees were not instructed to recognize the applicable energy sources, the magnitude of electrical energy, or how to isolate it for machines such as, but not limited to, the Injection Molded Plastic Collator, m/n PS160.  This violation was observed on 03/31/17.
Recent events (2)
  • — I (S) $0
  • — Z (S) $12675

1910.212 A01

Repeat Gravity 10 80 instances 80 exposed
Issued
Apr 20, 2017
Abate by
Nov 1, 2017
Penalty
Initial $63,375 · Current $38,000 Reduced
29 CFR 1910.212(a)(1):  One or more methods of machine guarding were not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    At 2700 Central Avenue, Poplar Bluff, MO, specifically inside of the Plastic Strip Department, the circular, fixed, barrier guard belonging to the Injection Molded Plastic Collator, m/n PS160, was not secured in place.  This violation was observed on 03/31/17.      At 2700 Central Avenue, Poplar Bluff, MO, specifically inside of the Plastic Strip Department, the ten straightening rollers attached to the Feed Roller Unit belonging to the ENKOTEC Machines were unguarded.  Employee(s) were exposed to an in-going nip point hazard.  This violation was observed on 03/31/17.    At 2700 Central Avenue, Poplar Bluff, MO, specifically inside of the Plastic Strip Department, the rotating spools of wire were unguarded.  These spools of wire were positioned in designated aisleways and in close proximity to the ENKOTEC Machines.  This violation was observed on 03/31/17.      Mid Continent Steel and Wire Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1910.212(a)(1), which was contained in OSHA inspection number 901373, citation 1,  item number 1, and was affirmed as a final order on 05/17/13, with respect to a workplace located at 2700 Central Avenue, Poplar Bluff, MO 63901.
Recent events (2)
  • — I (R) $38000
  • — Z (R) $63375

1910.303 B07 IV

Other-than-serious 1 instance 5 exposed
Issued
Apr 20, 2017
Abate by
Jun 7, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(7)(iv): There were damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating:  At 2700 Central Avenue, Poplar Bluff, MO, specifically inside of the Maintenance Department, the junction box providing 115 volt electrical power to a horizontal band saw was damaged.  The cover to this junction box was split wide open revealing the live, insulated wiring.  This violation was observed on 03/31/17.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View MID Continent Steel and Wire INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342209186.