Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ADVANCED WELDING, LLC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ADVANCED WELDING, LLC. in 1615 WEST STREET, SOUTHINGTON, CT 06489 (NAICS 238990). OSHA activity number 342212321.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Advanced Welding, LLC. — free Get an email when a new federal OSHA severe-injury report for Advanced Welding, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
1615 WEST STREET
City
SOUTHINGTON
State
CT
ZIP
06489
Mailing
125 ROBERT JACKSON WAY, UNIT H, PLAINVILLE, CT 06062
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
4
Ownership type
A

2 citations on file for this inspection.

1926.760 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 6, 2017
Penalty
Initial $2,987 · Current $2,091 Reduced
29 CFR 1926.760(a)(1): Each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems, or fall restraint systems.  On or about 03/29/2017 at the Cava Restaurant Construction Project, employees were working for the upper deck without any fall protection system in use.
Recent events (2)
  • — I (S) $2090.9
  • — Z (S) $2987

1926.300 B01

Other-than-serious 2 instances 2 exposed
Issued
Apr 6, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use:  On or about 03/29/2017 at the Cava Restaurant Construction Project, employees were using grinders without guards to grind the welds of the staircase.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Advanced Welding, LLC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342212321.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.