Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CPG BUILDING PRODUCTS

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CPG BUILDING PRODUCTS in 894 PRAIRIE AVE, WILMINGTON, OH 45177 (NAICS 321212). OSHA activity number 342279767.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch CPG Building Products — free Get an email when a new federal OSHA severe-injury report for CPG Building Products is published. One employer, no account, unsubscribe in one click.
Site address
894 PRAIRIE AVE
City
WILMINGTON
State
OH
ZIP
45177
Mailing
894 PRAIRIE AVE, WILMINGTON, OH 45177
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321212
Employees
420
Ownership type
A

2 citations on file for this inspection.

1910.147 D

Serious Gravity 10 16 instances 20 exposed
Issued
Aug 14, 2017
Abate by
Sep 29, 2017
Penalty
Initial $12,675 · Current $12,675
29 CFR 1910.147(d): Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence:  a: Employees performing servicing and maintenance inside of the mist tank were not required to:  (1)  Know the type and magnitude of the energy, the hazards of the energy to be controlled, and the method or means to control the energy, (2) turn off and shut down the machine (3)  physically locate and operate the energy isolating devices in such a manner as to isolate the machine or equipment from the energy source, (4) affix lockout or tagout devices to each energy isolating device, (5) prior to starting work on machines that have been locked out or tagged out, verify that isolation and deenergization of the machine or equipment have been accomplished.  On April 22, 2017, employee(s) cleaning and replacing mist nozzles were exposed to a caught-in hazard on the powered rollers in the mist tank located on line #14 in that the 480V electrical disconnect was not locked in the off position.
Recent events (1)
  • — Z (S) $12675

1910.212 A01

Serious Gravity 10 16 instances 20 exposed
Issued
Aug 14, 2017
Abate by
Sep 29, 2017
Penalty
Initial $12,675 · Current $12,675
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices,electronic safety devices, etc.  a) Employees in the HDPE (high density polyethylene) area were exposed to a caught in hazard on the powered rollers located inside of the 16 mist tanks, in that the barrier guards installed on top of the rollers are opened during production and employees reach through and around rotating rollers running at 87 rpm to access mist nozzles in the mist tank to clean or replace them daily.
Recent events (1)
  • — Z (S) $12675

View CPG Building Products's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342279767.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.