Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FRAS-LE NORTH AMERICA, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of FRAS-LE NORTH AMERICA, INC. in 103 ECHLIN BLVD., PRATTVILLE, AL 36067 (NAICS 336340). OSHA activity number 342346905.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fras-Le North America, INC. — free Get an email when a new federal OSHA severe-injury report for Fras-Le North America, INC. is published. One employer, no account, unsubscribe in one click.
Site address
103 ECHLIN BLVD.
City
PRATTVILLE
State
AL
ZIP
36067
Mailing
103 ECHLIN BLVD., PRATTVILLE, AL 36067
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336340
Employees
65
Ownership type
A

1 citation on file for this inspection.

1910.147 F01 II

Serious Gravity 10 1 instance 4 exposed
Issued
Aug 7, 2017
Abate by
Aug 24, 2017
Penalty
Initial $9,760 · Current $6,300 Reduced
29 CFR 1910.147(f)(1)(ii): When lockout or tagout devices temporarily were removed from the energy isolating device and the machine or equipment was energized to test or position the machine, the employees were not removed from the machine or equipment area in accordance to the paragraph (e)(2):   a) Production Floor; On or about May 12, 2017 the employer exposed employees to amputation hazards in that employees were required to troubleshoot - test or position - IAG #2 while the machine was energized. The employer failed to follow the required sequence of actions as set by the standard when equipment is energized for testing or positioning. Employees were not removed from the machine or equipment area prior to the machine being energized.
Recent events (2)
  • — I (S) $6300
  • — Z (S) $9760

View Fras-Le North America, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342346905.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.