Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FRAS-LE NORTH AMERICA, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of FRAS-LE NORTH AMERICA, INC. in 103 ECHLIN BLVD., PRATTVILLE, AL 36067 (NAICS 336340). OSHA activity number 346693583.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fras-Le North America, INC. — free Get an email when a new federal OSHA severe-injury report for Fras-Le North America, INC. is published. One employer, no account, unsubscribe in one click.
Site address
103 ECHLIN BLVD.
City
PRATTVILLE
State
AL
ZIP
36067
Mailing
103 ECHLIN BLVD., PRATTVILLE, AL 36067
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336340
Employees
70
Ownership type
A

7 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 3 instances 4 exposed
Issued
Oct 2, 2023
Abate by
Oct 20, 2023
Penalty
Initial $6,641 · Current $4,500 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  a)New automated brake press area; On or about May 8, 2023: the employer exposed employees to potential hazardous energies in that employees were required to work on equipment to include but not limited to the new automated brake press which had multiple energy sources such as electric, pneumatic and hydraulic without those employees being required to utilize machine specific lock out procedure(s) to ensure that those energy sources were controlled while the employees were performing maintenance, cleaning, or servicing on the machine(s).  b)Mixing area; On or about May 8, 2023: the employer exposed employees to potential hazardous energies in that employees were required to work on equipment to include but not limited to the new mixer which had multiple energy sources such as electric, pneumatic and hydraulic without those employees being required to utilize machine specific lock out procedure(s) to ensure that those energy sources were controlled while the employees were performing maintenance, cleaning, or servicing on the machine(s).  c)Mixing area; On or about May 8, 2023: the employer exposed employees to potential hazardous energies in that employees were required to work on equipment to include but not limited to the old mixer which had multiple energy sources such as electric, pneumatic and hydraulic without those employees being required to utilize machine specific lock out procedure(s) to ensure that those energy sources were controlled while the employees were performing maintenance, cleaning, or servicing on the machine(s).
Recent events (2)
  • — I (S) $4500
  • — Z (S) $6641

1910.147 C06 I

Serious Gravity 5 1 instance 7 exposed
Issued
Oct 2, 2023
Abate by
Oct 20, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(6)(i):The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  a)  Facility; On or about May 8, 2023: the employer exposed employees to potential hazardous energies in that the employer failed to conduct the required periodic inspection of the energy control procedures for machinery with multiple energy sources which includes but is not limited to mixers and brake press machines. Employees were required to work on these machines with procedures that had not been audited periodically as required by the standard so that any deviations or inadequacies would be discovered and corrected.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A03 II

Serious Gravity 5 5 instances 3 exposed
Issued
Oct 2, 2023
Abate by
Oct 20, 2023
Penalty
Initial $6,641 · Current $4,000 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):  a)  Manual press area; On or about May 8, 2023: the employer exposed employees to amputation hazards in that employees were allowed to operate a Williams White press H09 with unguarded pinch point between the machine frame and the press part carriage.  b)  Manual press area; On or about May 8, 2023: the employer exposed employees to amputation hazards in that employees were allowed to operate a Williams White press H010 with unguarded pinch point between the machine frame and the press part carriage.  c)  Manual press area; On or about May 8, 2023: the employer exposed employees to amputation hazards in that employees were allowed to operate a Williams White press H011 with unguarded pinch point between the machine frame and the press part carriage.  d)  Manual press area; On or about May 8, 2023: the employer exposed employees to amputation hazards in that employees were allowed to operate a Williams White press H012 with unguarded pinch point between the machine frame and the press part carriage.  e)  Small batch mix area; On or about May 8, 2023: the employer exposed employees to amputation hazards in that employees were allowed to operate a Littleford mixer 6453 (FNA0082) with unguarded pinch point between the machine frame and the mixer seal plate.
Recent events (2)
  • — I (S) $4000
  • — Z (S) $6641

1910.134 C01

Other-than-serious 1 instance 4 exposed
Issued
Oct 2, 2023
Abate by
Oct 27, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:  a)  Mixing Area; On or about May 8, 2023: the employer exposed employees to respiratory hazards in that employees were required to wear N95 respirators in the workplace without the employer establishing and implementing a written respiratory protection program with worksite-specific procedures.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 E01

Other-than-serious 1 instance 4 exposed
Issued
Oct 2, 2023
Abate by
Oct 27, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  a)  Mixing Area;  On or about May 8, 2023: the employer exposed employees to potential respiratory hazards in that employees were required to wear a tight fitting N95 negative pressure respirator without first being medically evaluated to ensure the employees are medically able to wear a negative pressure respirator.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 F01

Other-than-serious 1 instance 4 exposed
Issued
Oct 2, 2023
Abate by
Oct 27, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT):  a)  Mixing Area;  On or about May 8, 2023: the employer exposed employees to potential respiratory hazards in that employees were required to wear N95 negative pressure respirators without first being fit tested.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 K03

Other-than-serious 1 instance 4 exposed
Issued
Oct 2, 2023
Abate by
Oct 27, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k)(3): Training was not provided prior to requiring employees to use a respirator in the workplace:  a)  Mixing Area;  On or about May 8, 2023: the employer exposed employees to potential respiratory hazards in that employees were required to wear N95 negative pressure respirator without first being provided training as required by the standard.