AVON, OH —
OSHA Inspection: ON TOP ROOFING & RENOVATIONS LLC
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of ON TOP ROOFING & RENOVATIONS LLC in 35290 DETROIT RD., AVON, OH 44011 (NAICS 238990). OSHA activity number 342360187.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ON TOP ROOFING & RENOVATIONS LLC
- Site address
- 35290 DETROIT RD.
- City
- AVON
- State
- OH
- ZIP
- 44011
- Mailing
- 5704 BRIDGE AVE, CLEVELAND, OH 44102
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238990
- Employees
- 8
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.100 A
- Issued
- Aug 7, 2017
- Abate by
- Aug 17, 2017
- Penalty
- Initial $3,803 · Current $3,803
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: On or about May 23, 2017, the employer did not ensure that employees working on the ground level were protected from falling materials and tools from the work being performed overhead.
Recent events (1)
- — Z (S) $3803
1926.102 A01
- Issued
- Aug 7, 2017
- Abate by
- Aug 15, 2017
- Penalty
- Initial $3,803 · Current $3,803
General-duty citation text
29 CFR 1926.102(a)(1): 29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation. On or about May 23, 2017, the employer failed to ensure that employees engaged in roofing activities including tear off and shingling were protected by flying particles. Employees were utilizing pneumatic air guns without out the use of safety rated glasses.
Recent events (1)
- — Z (S) $3803
1926.451 G01 I
- Issued
- Aug 7, 2017
- Abate by
- Aug 15, 2017
- Penalty
- Initial $3,803 · Current $3,803
General-duty citation text
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold shall be protected by a personal fall arrest system. On or about May 23, 2017, the employer failed to ensure that employees working from a ladder jack scaffold were protected from falling to the level below by the use of personal fall arrest systems.
Recent events (1)
- — Z (S) $3803
1926.501 B13
- Issued
- Aug 7, 2017
- Abate by
- Aug 15, 2017
- Penalty
- Initial $3,803 · Current $3,803
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): On or about May 23, 2017, the employer failed to ensure that employees engaged in roofing activities of a residential home were protected from falling to the ground below by use of fall protection devices. Employees were working at height varying between 15 and 25 feet on a roof having a 10/12 pitch without the use of fall protection devices.
Recent events (1)
- — Z (S) $3803
1926.1053 B01
- Issued
- Aug 7, 2017
- Abate by
- Aug 17, 2017
- Penalty
- Initial $2,716 · Current $2,716
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: On or about May 23, 2017, the employer failed to ensure that ladders used by employees for ascending and descending from a residential roof were extended at least 3 feet. Employees were utilizing the ladders to access the roof to perform shingle work.
Recent events (1)
- — Z (S) $2716
More inspections at On TOP Roofing & Renovations LLC
View On TOP Roofing & Renovations LLC's full OSHA safety record →
More inspections in this industry (NAICS 238990)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342360187.